2022
DOI: 10.3390/nano12213854
|View full text |Cite
|
Sign up to set email alerts
|

Lithographic SERS Aptasensor for Ultrasensitive Detection of SARS-CoV-2 in Biological Fluids

Abstract: In this paper, we propose a technology for the rapid and sensitive detection of the whole viral particles of SARS-CoV-2 using double-labeled DNA aptamers as recognition elements together with the SERS method for detecting the optical response. We report on the development of a SERS-aptasensor based on a reproducible lithographic SERS substrate, featuring the combination of high speed, specificity, and ultrasensitive quantitative detection of SARS-CoV-2 virions. The sensor makes it possible to identify SARS-CoV… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(7 citation statements)
references
References 32 publications
0
7
0
Order By: Relevance
“…Resonant Raman compounds, i.e., cyanine three (Cy3) or tetramethylrodamine (TAMRA) fluorescent dyes, were introduced at the 5 ends of the aptamers (Figure 2). The same approach was used in previous work for the RBD-1C aptamer [8]. The ratio of surface-enhanced Raman signal to fluorescence intensity was decreased in the presence of the virus, providing an excellent limit of detection of SARS-CoV-2 of 100 copies/mL.…”
Section: Setup Of the Aptasensormentioning
confidence: 81%
See 3 more Smart Citations
“…Resonant Raman compounds, i.e., cyanine three (Cy3) or tetramethylrodamine (TAMRA) fluorescent dyes, were introduced at the 5 ends of the aptamers (Figure 2). The same approach was used in previous work for the RBD-1C aptamer [8]. The ratio of surface-enhanced Raman signal to fluorescence intensity was decreased in the presence of the virus, providing an excellent limit of detection of SARS-CoV-2 of 100 copies/mL.…”
Section: Setup Of the Aptasensormentioning
confidence: 81%
“…The overall setup is similar to the previously published one [8]. The aptamers were immobilized on the lithographic metal surface, whereas viruses were captured from liquid samples.…”
Section: Setup Of the Aptasensormentioning
confidence: 99%
See 2 more Smart Citations
“…It is especially significant for analyte determination with low limit of detection ( Kraemer et al, 2011 ). An example of usage of double modified aptamer in SERS-based technique is provided in our recent work ( Kukushkin et al, 2022a ). In that work the aptamer was immobilized onto the metal surface through a thiol group, whereas the Cyanine-3 dye was used as a reporter which signal decreased when the coronavirus (SARS-CoV-2 virus) bound to the aptamer.…”
Section: Introductionmentioning
confidence: 99%