2001
DOI: 10.1016/s0921-5093(01)01066-8
|View full text |Cite
|
Sign up to set email alerts
|

Localized heating during serrated plastic flow in bulk metallic glasses

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

12
125
1
2

Year Published

2003
2003
2016
2016

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 286 publications
(140 citation statements)
references
References 14 publications
12
125
1
2
Order By: Relevance
“…The curves demonstrate that the material exhibits the maximum fracture stress of about 430 MPa at a dynamic strain rate of 1.0!10 3 s K1 and about 360 MPa at a quasi-static strain rate of 6.0!10 K4 s K1 . At quasi-static loading conditions, the flow is noted to be serrated, this is similar to that observed previously in Zr-based [32] and Pd-based [33] BMGs. Also, serrated flow has been proposed to be associated with the emission of localized shear bands [32].…”
Section: Resultssupporting
confidence: 87%
See 1 more Smart Citation
“…The curves demonstrate that the material exhibits the maximum fracture stress of about 430 MPa at a dynamic strain rate of 1.0!10 3 s K1 and about 360 MPa at a quasi-static strain rate of 6.0!10 K4 s K1 . At quasi-static loading conditions, the flow is noted to be serrated, this is similar to that observed previously in Zr-based [32] and Pd-based [33] BMGs. Also, serrated flow has been proposed to be associated with the emission of localized shear bands [32].…”
Section: Resultssupporting
confidence: 87%
“…At quasi-static loading conditions, the flow is noted to be serrated, this is similar to that observed previously in Zr-based [32] and Pd-based [33] BMGs. Also, serrated flow has been proposed to be associated with the emission of localized shear bands [32].…”
Section: Resultssupporting
confidence: 87%
“…This explains why liquid-like morphologies such as the vein-patterns and liquid droplets are often seen in real metallic glass samples, especially after extensive deformation and fracture. 2,3,[27][28][29] For metallic glasses that are intrinsically brittle with little or no accumulated strain, they would exhibit far less liquid-like fracture in surface morphologies or diminishing scales in the vein-patterns. 30) Furthermore, the homogeneous deformation as seen in the tensile simulation suggests that the shear localization may not be the only mechanism for deformation in metallic glasses at low temperatures.…”
Section: )mentioning
confidence: 99%
“…рис. 3) показывают ре-гулярные сбросы нагрузки, которые характерны для многих ОМС [84], то во время тестирования при криогенных температурах зубцы на кривой не появляются (по крайней мере в пределах чувстви-тельности используемой экспериментальной уста-новки). Отсутствие или наличие скачков нагрузки на деформационной кривой объясняется соотно-шением конкурирующих процессов: сдвиговыми смещениями в образце за счет образования и рас-пространения зон избыточного объема в полосах скольжения и диффузионными перестройками искаженной структуры как внутри этих полос, так и на их фронте.…”
Section: механические свойства омс при криогенной температуреunclassified