2006
DOI: 10.1109/iembs.2006.4397886
|View full text |Cite
|
Sign up to set email alerts
|

Long-Term Characterization of Electrode Materials for Surface Electrodes in Biopotential Recording

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
12
1

Year Published

2016
2016
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(13 citation statements)
references
References 0 publications
0
12
1
Order By: Relevance
“…More specifically, we decided to use 10-mm sintered silver-silver chloride electrode disks (Figure 2a), which proved to be more electrically stable for long-term operation than Ag/AgCl electrodes manufactured with a galvanization process [23,24], offering advantages of relatively low impedance, being re-usable (in one subject) and long-lasting. They also have a non-polarizable behavior and higher mechanical stability than regular silver-silver chloride electrodes [25].…”
Section: Dry Ecg Electrode Systemmentioning
confidence: 99%
“…More specifically, we decided to use 10-mm sintered silver-silver chloride electrode disks (Figure 2a), which proved to be more electrically stable for long-term operation than Ag/AgCl electrodes manufactured with a galvanization process [23,24], offering advantages of relatively low impedance, being re-usable (in one subject) and long-lasting. They also have a non-polarizable behavior and higher mechanical stability than regular silver-silver chloride electrodes [25].…”
Section: Dry Ecg Electrode Systemmentioning
confidence: 99%
“…Each of these materials must provide flexibility to improve contact during movement of the individual. Based on this flexibility, designs can be found with conductive foam [ 14 ], conducting polymers (poly (3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS)) and polymers with conductive particles (silver) [ 15 ], nanoparticles [ 16 ], or carbon nanotubes [ 17 ]. As for the location of the electrodes, there are works published in the literature with electrodes arranged in different positions on T-shirts, vests, girdles, and swimsuits [ 18 , 19 , 20 ].…”
Section: Introductionmentioning
confidence: 99%
“…Ag/AgCl electrodes have low half-cell potential and also show similar characteristics to perfectly nonpolarizable electrodes. A comprehensive long-term study of surface electrode materials was performed in 0.9% NaCl solution by Hoffmann et al [14]. It was shown that nonpolarizable electrodes (e.g.…”
Section: Introductionmentioning
confidence: 99%