Long‐term evaluation and cross‐checking of two geometric calibrations of kV and MV imaging systems for Linacs

Abstract: Geometric or mechanical accuracy of kV and MV imaging systems of two Varian TrueBeam linacs have been monitored by two geomertirc calibration systems, Varian IsoCal geometric calibration system and home‐developed gQA system. Results of both systems are cross‐checked and the long‐term geometric stabilities of linacs are evaluated. Two geometric calibration methodologies have been used to assess kV and MV imaging systems and their coincidence periodically on two TrueBeam linacs for about one year. Both systems a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 8 publications
0
6
0
Order By: Relevance
“…For accurate IGRT the imaging system and radiation isocenters must coincide . This is achieved on Varian linacs using the IsoCal calibration procedure, which has been validated by Gao et al, 2014 and by Chiu et al, 2015 . The kV and MV systems share a common axis of gantry rotation.…”
Section: Methodsmentioning
confidence: 99%
“…For accurate IGRT the imaging system and radiation isocenters must coincide . This is achieved on Varian linacs using the IsoCal calibration procedure, which has been validated by Gao et al, 2014 and by Chiu et al, 2015 . The kV and MV systems share a common axis of gantry rotation.…”
Section: Methodsmentioning
confidence: 99%
“…Both ETX and CBCT were previously calibrated to the machine radiation isocenter. An IsoCal calibration [11] was performed to calibrate the CBCT. The Winston-Lutz [7] test was thereafter performed with a pointer to calibrate ETX to the radiation isocenter.…”
Section: Setup and Irradiationmentioning
confidence: 99%
“…Another 8 DOF approach to geometric quality assurance is the work by Mao et al that introduced the gQA phantom that characterize source position and imager deformations for both MV and kV imaging. The long‐term stability and accuracy of this system has already been evaluated . However, some DOF in the system are neglected.…”
Section: Introductionmentioning
confidence: 99%
“…The longterm stability and accuracy of this system has already been evaluated. 5 However, some DOF in the system are neglected. Indeed, gantry rotations around every axis should be measured.…”
Section: Introductionmentioning
confidence: 99%