Low contrast and radiation dose coronary CT angiography using a 320-row system and a refined contrast injection and timing method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
47
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 59 publications
(49 citation statements)
references
References 39 publications
2
47
0
Order By: Relevance
“…The main findings of our study are that, in patients with low body weight, image quality, coronary evaluability and diagnostic accuracy of low-dose lowiodine coronary CTA are high and similar to those reported in the literature for standard tube voltage and iodine load protocols. Accordingly with previous studies performed with low kV approach (until 70 kV) and iterative reconstruction (10,11), the present study showed good image quality and low radiation exposure. We rated 61.5% of coronary images of excellent quality.…”
Section: Discussionsupporting
confidence: 88%
“…The main findings of our study are that, in patients with low body weight, image quality, coronary evaluability and diagnostic accuracy of low-dose lowiodine coronary CTA are high and similar to those reported in the literature for standard tube voltage and iodine load protocols. Accordingly with previous studies performed with low kV approach (until 70 kV) and iterative reconstruction (10,11), the present study showed good image quality and low radiation exposure. We rated 61.5% of coronary images of excellent quality.…”
Section: Discussionsupporting
confidence: 88%
“…22,23 However, image noise is also increased in the range of 16-81%, 22,24 which allows further decrease of the tube energy to 80 kV only in children and adults with low BMI. 21,25 A more extensive discussion falls outside the scope of this review.…”
Section: Image Quality Improvement Strategiesmentioning
confidence: 99%
“…19,24 A further improvement in CNR could be achieved by alteration of reconstruction methods, for example, with the implementation of iterative reconstruction. [25][26][27] However, subjective image quality will not always be experienced as superior owing to possible loss of contrast between different densities.…”
Section: Discussionmentioning
confidence: 99%
“…Already some advancements have been made using lower kV settings in CTA. [25][26][27][36][37][38] A decrease in kV increases intraarterial CM attenuation, because the higher photon energy at lower kV settings is closer to the iodine k-edge of keV. 4,24,39,40 Many studies focused on low kV protocols; however, one must ensure to concordantly increase mAs to avoid excessive image noise.…”
Section: Discussionmentioning
confidence: 99%