2022
DOI: 10.1016/j.snb.2022.131961
|View full text |Cite
|
Sign up to set email alerts
|

Low-cost Internet of Things (IoT)-enabled a wireless wearable device for detecting potassium ions at the point of care

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 31 publications
(8 citation statements)
references
References 65 publications
0
8
0
Order By: Relevance
“…The primary physiologically significant indicators and their dynamic concentration levels in human sweat are listed in Table 4 . Sweat contains substantial concentrations of lactate [ 282 , 283 , 284 , 285 ], glucose [ 286 , 287 , 288 , 289 , 290 ], uric acid [ 291 , 292 ], ascorbic acid [ 293 , 294 , 295 ], cortisol [ 296 , 297 ], tyrosine [ 298 , 299 ], ethyl glucuronide [ 300 ], F17464 [ 301 ], Na + [ 302 , 303 , 304 , 305 ], Cl − [ 306 , 307 ], K + [ 308 , 309 ], pH [ 310 , 311 , 312 ], NH 4+ [ 313 ], Ca 2+ [ 314 ], Zn 2+ [ 315 ] and Cd 2+ [ 316 ]. Because of their high sensitivity and ease of development in small electronic circuits, the majority of sweat sensors use amperometric and potentiometric transduction methods.…”
Section: Biosensors For Sweat Analysismentioning
confidence: 99%
“…The primary physiologically significant indicators and their dynamic concentration levels in human sweat are listed in Table 4 . Sweat contains substantial concentrations of lactate [ 282 , 283 , 284 , 285 ], glucose [ 286 , 287 , 288 , 289 , 290 ], uric acid [ 291 , 292 ], ascorbic acid [ 293 , 294 , 295 ], cortisol [ 296 , 297 ], tyrosine [ 298 , 299 ], ethyl glucuronide [ 300 ], F17464 [ 301 ], Na + [ 302 , 303 , 304 , 305 ], Cl − [ 306 , 307 ], K + [ 308 , 309 ], pH [ 310 , 311 , 312 ], NH 4+ [ 313 ], Ca 2+ [ 314 ], Zn 2+ [ 315 ] and Cd 2+ [ 316 ]. Because of their high sensitivity and ease of development in small electronic circuits, the majority of sweat sensors use amperometric and potentiometric transduction methods.…”
Section: Biosensors For Sweat Analysismentioning
confidence: 99%
“…According to our previous procedure, the ion-selective membranes (ISM) for fabrication of Na + -ISE and K + -ISE were prepared. 32,33 While 2% (w/w) of sodium ionophore I, 0.5% (w/w) of NaTCPB, 65% (w/w) of DOS, and 32.5% (w/w) of PVC were mixed in 2 mL THF for Na + -ISM, 2% (w/w) of potassium ionophore I, 0.6% (w/w) of KTCPB, 64.7% (w/w) of DOS, and 32.7% (w/w) of PVC were mixed in 1.5 mL THF for the preparation K + -ISM. 200 mg of the reference electrode membrane consists of 73% (w/w) of poly(butyl methacrylate-co-methyl methacrylate), 25% (w/w) of KCl, and 2% (w/w) of tetradodecyammonium tetrakis (4-chlorophenyl) borate were mixed in 1 mL THF and sonicated for 15 min to prepare reference electrode membrane.…”
Section: Preparation Of Ion-selective Membranesmentioning
confidence: 99%
“…These kinds of tools are able to connect with other devices or systems. It assists to improve the work and production flow with zero human error and these applications are easier to use [2]. Accordingly, point-of-care technologies and applications have their own network system that helps to connect all the data and also provides the logical conclusion or result for the process of working.…”
Section: Connections Of Iot and Poc With Biomedical Engineering And H...mentioning
confidence: 99%