2024
DOI: 10.1016/j.gie.2023.07.025
|View full text |Cite
|
Sign up to set email alerts
|

Low delayed bleeding and high complete closure rate of mucosal defects with the novel through-the-scope dual-action tissue clip after endoscopic resection of large nonpedunculated colorectal lesions (with video)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
5
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 13 publications
(5 citation statements)
references
References 29 publications
0
5
0
Order By: Relevance
“…It cannot be rotated so requires manipulation of the scope dials for positioning and operating the independent jaws can be difficult with endoscope looping. [10] The MANTIS is operated similarly to a standard TTSC. It may have a lower learning curve for both endoscopist and technician than alternative devices.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…It cannot be rotated so requires manipulation of the scope dials for positioning and operating the independent jaws can be difficult with endoscope looping. [10] The MANTIS is operated similarly to a standard TTSC. It may have a lower learning curve for both endoscopist and technician than alternative devices.…”
Section: Discussionmentioning
confidence: 99%
“…This clip features two independent arms and is efficacious in closing large resection defects. Because it cannot be rotated, it requires manipulation of the scope dials for positioning and operating the independent jaws can be difficult with endoscope looping 10 . The MANTIS is operated similarly to a standard TTSC.…”
Section: Discussionmentioning
confidence: 99%
“…42 More recently, we performed a multicenter prospective study demonstrating low delayed bleeding and high complete closure rate of mucosal defects with the DAT clip after endoscopic resection of large nonpedunculated colorectal lesions. 43 Data from this ongoing prospective registry demonstrated complete closure rate of 96% of postresection defects with a median size of 40 mm when using an average of one DAT and two conventional TTS clips. Delayed bleeding based on 30day follow-up was encountered in only one patient (0.9%).…”
Section: Technical Considerationsmentioning
confidence: 94%
“…has revealed a complete closure rate of 96.3% of EMR or ESD defects with a median size of 40 mm in diameter by using this clip. 49 …”
Section: Introductionmentioning
confidence: 99%