Abstract:This paper proposes a selective harmonic elimination technique for medium and high power three phase cascaded H-bridges l-level inverters at fundamental frequency. Compared to other SHE methods, it is capable to delete more harmonics from the output voltage waveform and to provide lower total harmonic distortion values. A mathematical proof is given to demostrate that undeleted harmonics are only those of order n = 2k (l + r) ± 1, k = 1, 2, . . ., where r is an integer parameter that assumes the values −2, −1,… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.