2000
DOI: 10.1541/ieejeiss1987.120.7_910
|View full text |Cite
|
Sign up to set email alerts
|

Low Noise Blue Light Generation of Intracavity Frequency Doubled LD Pumped Cr:LiSAF Laser by Single Mode Method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2012
2012
2012
2012

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 9 publications
0
4
0
Order By: Relevance
“…For example, the corresponding optical-to-optical and electrical-to-optical blue conversion efficiencies of the system are about 2.4% and 0.7%, respectively. For comparison, the obtained optical-to-optical conversion efficiencies are mostly better than what has been achieved with Cr:LiSAF (0.37 mW blue power with 350 mW of pump power, 0.11% efficiency [27], 20 mW blue power with 3 W of pump power, 0.66% efficiency [25], 13 mW blue with 700 mW of pump power, 1.86% efficiency [26], 32 mW blue power with 1 W of pump power, 3.2% efficiency [28]). Certainly, the results of this study were only possible due to the low-loss Cr:LiCAF crystal and optics we have utilized, which enabled the construction of a high-Q laser cavity with intracavity laser powers around 30 W.…”
Section: B Continuous-wave Tunable Blue Generation Resultsmentioning
confidence: 64%
See 2 more Smart Citations
“…For example, the corresponding optical-to-optical and electrical-to-optical blue conversion efficiencies of the system are about 2.4% and 0.7%, respectively. For comparison, the obtained optical-to-optical conversion efficiencies are mostly better than what has been achieved with Cr:LiSAF (0.37 mW blue power with 350 mW of pump power, 0.11% efficiency [27], 20 mW blue power with 3 W of pump power, 0.66% efficiency [25], 13 mW blue with 700 mW of pump power, 1.86% efficiency [26], 32 mW blue power with 1 W of pump power, 3.2% efficiency [28]). Certainly, the results of this study were only possible due to the low-loss Cr:LiCAF crystal and optics we have utilized, which enabled the construction of a high-Q laser cavity with intracavity laser powers around 30 W.…”
Section: B Continuous-wave Tunable Blue Generation Resultsmentioning
confidence: 64%
“…In the intracavity cw blue generation experiments with Cr:LiSAF, cw blue powers up to 32 mW at 430 nm have been reached from a Cr:LiSAF laser pumped by a 1 W diode [28]. Moreover, cw blue tuning ranges from 428 to 444 nm [26] and q-switched blue tuning ranges from 390 to 480 nm [16] have been achieved.…”
Section: Introductionmentioning
confidence: 97%
See 1 more Smart Citation
“…With its demonstrated cw tuning range in this study (from 780 to 1110 nm), it also has one of the largest fractional tuning ranges (0.35) among all solid-state gain media. Lastly, earlier studies indicate that, using cw intracavity second harmonic generation, the tuning range of Cr:LiSAF lasers might be extended into the blue to green regions of the optical spectrum [59][60][61][62]. This spectral region is of great interest for several applications including imaging, remote atmospheric sensing, medical diagnosis, and information storage.…”
Section: B Tuning the Cw Lasermentioning
confidence: 99%