2018
DOI: 10.2172/1459799
|View full text |Cite
|
Sign up to set email alerts
|

Low Temperature Aluminum Dissolution (LTAD) Real Waste Testing of the November 2017 Tank 51 Slurry Sample

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
11
0

Year Published

2018
2018
2020
2020

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(11 citation statements)
references
References 0 publications
0
11
0
Order By: Relevance
“…The weight percent total solids, dissolved solids (supernate basis), insoluble solids, as well as the supernate and slurry densities were reported previously on this pre-SB10 Tank 51 sample 11 and are summarized in Table 3-1 There was insufficient sample to apply Purge & Trap methods to this second tank slurry sample. Since it was not possible to measure volatile mercury species via purge and trap on the parent sample, the volatile species were measured on diluted samples of supernatant liquid as discussed in the next section.…”
Section: Htf-51-17-112 Propertiesmentioning
confidence: 93%
“…The weight percent total solids, dissolved solids (supernate basis), insoluble solids, as well as the supernate and slurry densities were reported previously on this pre-SB10 Tank 51 sample 11 and are summarized in Table 3-1 There was insufficient sample to apply Purge & Trap methods to this second tank slurry sample. Since it was not possible to measure volatile mercury species via purge and trap on the parent sample, the volatile species were measured on diluted samples of supernatant liquid as discussed in the next section.…”
Section: Htf-51-17-112 Propertiesmentioning
confidence: 93%
“…The validation data set may be included in the linear regression to improve the quality and robustness of the Reillex HGR model. The enhanced model achieved by including the validation data set in the linear regression is given in Equation [30].…”
Section: Model Validation Experimentsmentioning
confidence: 99%
“…The HGR results of all Reillex testing are plotted against the enhanced Reillex model described in Equation [30] in Figure 3-37. The results plotted in Figure 3-37 show that the majority of testing with Reillex HPQ resin digestion product material are generally well-described by the model expression given in Equation [30]. All the original model generation data and the validation data sets fall within the 95% confidence limit for a single prediction.…”
Section: Model Validation Experimentsmentioning
confidence: 99%
See 2 more Smart Citations