2013
DOI: 10.1016/j.measurement.2013.06.031
|View full text |Cite
|
Sign up to set email alerts
|

Magnetic resonance butterfly coils: Design and application for hyperpolarized 13C studies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 11 publications
(7 citation statements)
references
References 20 publications
0
7
0
Order By: Relevance
“…Magnetic field estimation method was experimentally verified by workbench measurement on birdcage coil 20 and by extracting magnetic field profiles in B 1 maps acquired with a solenoid 5 and an elliptical surface coil. 21 T A B L E 4 Estimated magnetic field per unit current (CL, circular loop with b radius; SL, square loop with S side) Analytical calculation employed for inductance estimation was experimentally verified by workbench measurement on birdcage coil 20 and on 13 C butterfly coils, 22 showing resonant frequency deviations lower than 2.2% and 5.2% for, respectively, birdcage and butterfly, compatible with the capacitor tolerances used in the coils construction. Moreover, mutual inductance calculations performed on phased-array of circular and rectangular loops confirmed literature empirical data in terms of mutual interaction patterns.…”
Section: Discussionmentioning
confidence: 82%
See 1 more Smart Citation
“…Magnetic field estimation method was experimentally verified by workbench measurement on birdcage coil 20 and by extracting magnetic field profiles in B 1 maps acquired with a solenoid 5 and an elliptical surface coil. 21 T A B L E 4 Estimated magnetic field per unit current (CL, circular loop with b radius; SL, square loop with S side) Analytical calculation employed for inductance estimation was experimentally verified by workbench measurement on birdcage coil 20 and on 13 C butterfly coils, 22 showing resonant frequency deviations lower than 2.2% and 5.2% for, respectively, birdcage and butterfly, compatible with the capacitor tolerances used in the coils construction. Moreover, mutual inductance calculations performed on phased-array of circular and rectangular loops confirmed literature empirical data in terms of mutual interaction patterns.…”
Section: Discussionmentioning
confidence: 82%
“…Analytical calculation employed for inductance estimation was experimentally verified by workbench measurement on birdcage coil and on 13 C butterfly coils, showing resonant frequency deviations lower than 2.2% and 5.2% for, respectively, birdcage and butterfly, compatible with the capacitor tolerances used in the coils construction. Moreover, mutual inductance calculations performed on phased‐array of circular and rectangular loops confirmed literature empirical data in terms of mutual interaction patterns …”
Section: Discussionmentioning
confidence: 89%
“…The quadrature surface coil, consisting of a combination of the butterfly and the circular coil, was previously designed and tested as TX/RX configuration. The obtained SNR was higher as compared with the SNRs provided by the single coils in a wide range of the penetration depth into the phantom (Figure 10), while the MR acquisition of metabolic maps with hyperpolarized [1-13 C]pyruvate injected in a pig showed that the configuration was able to effectively image the hyperpolarized [1-13 C]pyruvate distribution, Successively, the same quadrature surface coil was used in RX mode in combination with a birdcage coil as a transmitter [66]. For this purpose, a passive decoupling circuit was added to both surface coils, as described in a previous paragraph.…”
Section: Quadrature Surface Coil In Tx/rx and Rx Onlymentioning
confidence: 99%
“…The theoretical SNR trends of dependence on the depth profile along the sample region (from 2 to 12 cm) are shown in Figure 10 for all coil configurations. was able to effectively image the hyperpolarized [1-13 C]pyruvate distribution, Successively, the same quadrature surface coil was used in RX mode in combination with a birdcage coil as a transmitter [66]. For this purpose, a passive decoupling circuit was added to both surface coils, as described in a previous paragraph.…”
Section: Theoretical Comparison Between 13 C Coil Snr Plotsmentioning
confidence: 99%
“…A comparison between a commercial 13 C quadrature birdcage coil and a homebuilt 13 C circular coil, both designed for hyperpolarized studies of the porcine heart with a clinical 3T scanner, was introduced in [8], and was carried out in terms of sensitivity regions and SNR. Furthermore two RX butterfly coils were presented with different geometries for 13 C hyperpolarized studies of pigs [9]; experimental SNR profiles acquired in a phantom highlight the advantage of this configuration over a volume birdcage coil in a wide range of coil-to-voxel distances.…”
Section: Introductionmentioning
confidence: 99%