1993
DOI: 10.1016/0730-725x(93)90222-y
|View full text |Cite
|
Sign up to set email alerts
|

Magnetic resonance methods for measurement of disease progression in rheumatoid arthritis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
18
0
1

Year Published

1997
1997
2006
2006

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 37 publications
(19 citation statements)
references
References 10 publications
0
18
0
1
Order By: Relevance
“…One major problem with the validation of Vsm determination by MRI lies in the identification of appropriate gold standards. A semi-automated method based on computerized counting of pixels fulfilling certain criteria can be used [16,17,18,19], volume measurements can be restricted to one or few slices per joint, or a semi-quantitative grading of synovial hypertrophy can be performed [3,20,21,22]. These methods are less time-consuming and faster and more attractive for applicability in larger clinical studies or in clinical routine.…”
Section: Discussionmentioning
confidence: 99%
“…One major problem with the validation of Vsm determination by MRI lies in the identification of appropriate gold standards. A semi-automated method based on computerized counting of pixels fulfilling certain criteria can be used [16,17,18,19], volume measurements can be restricted to one or few slices per joint, or a semi-quantitative grading of synovial hypertrophy can be performed [3,20,21,22]. These methods are less time-consuming and faster and more attractive for applicability in larger clinical studies or in clinical routine.…”
Section: Discussionmentioning
confidence: 99%
“…The volume estimations have been obtained either by manual computer-assisted outlining based on visual analysis of the images (9-12,15), as in the present study, or by semiautomatic computerized counting of pixels with a post-Gd-DTPA signal enhancement above a certain threshold (13,14,23). The semiautomatic methods are very sensitive to the enhancement thresholds chosen (23). Manual methods appear more reliable but are also more time consuming.…”
Section: Discussionmentioning
confidence: 99%
“…Quantitation of fluid and pannus volumes used methods similar to those published elsewhere 28 9 Briefly, fluid volume was obtained from T2 weighted (PSIF) scans by manual segmentation using Siemens image analysis software. The area calculated for each slice was multiplied by the slice separation to give the total volume.…”
Section: Methodsmentioning
confidence: 99%