2023
DOI: 10.1021/acssensors.3c00342
|View full text |Cite
|
Sign up to set email alerts
|

Magnetically Modulated Differential Quartz Crystal Microbalances for Rapid, Ultrasensitive, and Direct Probing of Prostate-Specific Antigens Conjugated with Magnetic Beads

Dongyu Chen,
Yumei Wen,
Ping Li
et al.

Abstract: The occurrence and development of diseases are closely related to overexpression of specific biomarkers in the serum of patients. Rapid and sensitive biomarker detection is beneficial for early diagnosis and treatment. However, the current laboratory processes and assays for biomarker detection are expensive and time-consuming, and their operation also requires a large number of professionals. We developed a magnetically modulated differential quartz crystal microbalance (MMD-QCM) method combined with magnetic… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 47 publications
0
3
0
Order By: Relevance
“…When the magnetic particles are loaded on the oscillating QCM, the magnetization motion will be modulated to the oscillation, obtaining a modulation signal with a frequency of ω q ± 2ω m . ,, The output signal x ( t ) can be expressed as x ( t ) = ξ F t = ξ 6 π η r h 2 D P 2 + false( 2 ω m false) 2 P cos [ false( ω q + 2 ω m false) t ] + ξ 6 π η r h 2 D P 2 + false( 2 ω m false) 2 2 ω m sin [ false( ω q + 2 ω m false) t ] where the coefficient ξ reflects the response effect of the QCM oscillation with respect to F t . Although the magnitude of x ( t ) is associated with HD, ξ is determined by both the QCM device parameters and the carrier solution.…”
Section: Theoretical Sectionmentioning
confidence: 99%
See 1 more Smart Citation
“…When the magnetic particles are loaded on the oscillating QCM, the magnetization motion will be modulated to the oscillation, obtaining a modulation signal with a frequency of ω q ± 2ω m . ,, The output signal x ( t ) can be expressed as x ( t ) = ξ F t = ξ 6 π η r h 2 D P 2 + false( 2 ω m false) 2 P cos [ false( ω q + 2 ω m false) t ] + ξ 6 π η r h 2 D P 2 + false( 2 ω m false) 2 2 ω m sin [ false( ω q + 2 ω m false) t ] where the coefficient ξ reflects the response effect of the QCM oscillation with respect to F t . Although the magnitude of x ( t ) is associated with HD, ξ is determined by both the QCM device parameters and the carrier solution.…”
Section: Theoretical Sectionmentioning
confidence: 99%
“…When the magnetic particles are loaded on the oscillating QCM, the magnetization motion will be modulated to the oscillation, obtaining a modulation signal with a frequency of ω q ± 2ω m . 56,59,80 The output signal x(t) can be expressed as…”
Section: ■ Theoretical Sectionmentioning
confidence: 99%
“…Prostate cancer poses a grave threat to male health, accounting for a staggering 26% of male malignant tumor incidence rates worldwide, ranking at the forefront. , Prostate-specific antigen (PSA), serving as a diagnostic marker for prostate cancer, is widely employed to indicate the onset and progression stages of the disease. , Consequently, the development and implementation of high-sensitivity PSA detection methods have emerged as a focal point in the realm of prostate cancer prevention and treatment. To improve the precision and dependability of PSA detection, novel techniques and methods were explored, such as an enzyme-linked immunosorbent assay (ELISA) a field transistor biosensor, , a quartz crystal microbalance, and microfluidic technology . Among them, widely reported ELISA was recognized by researchers for its high sensitivity and quantification capabilities. ,, However, reliable PSA results through ELISA require specialized equipment, trained personnel, and a consistent laboratory environment. ,, Accordingly, the application of ELISA in point-of-care testing (POCT) is hindered by the extended detection time, demanding requirements, and complex operation. …”
Section: Introductionmentioning
confidence: 99%