2018
DOI: 10.1109/jsen.2018.2840225
|View full text |Cite
|
Sign up to set email alerts
|

Magneto-Optical Device Based on Polarization Sensitivity for Perspective Biosensing Applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
12
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 15 publications
(13 citation statements)
references
References 38 publications
1
12
0
Order By: Relevance
“…However, as the TMOKE is observed only in the p-polarization of the incident light, this approach does not allow to perform magneto-optical measurements in a dual-channel regime for a simultaneous detection of the bulk and surface refractive indices of the analyte. Similar increase of the sensitivity was predicted for the polarization-based measurements in the polar configuration of a magnetic field for a case when the resonances in p- and s-polarizations coincide [ 33 ]. However, it also does not provide any possibility for the dual-channel measurements.…”
Section: Introductionsupporting
confidence: 72%
See 1 more Smart Citation
“…However, as the TMOKE is observed only in the p-polarization of the incident light, this approach does not allow to perform magneto-optical measurements in a dual-channel regime for a simultaneous detection of the bulk and surface refractive indices of the analyte. Similar increase of the sensitivity was predicted for the polarization-based measurements in the polar configuration of a magnetic field for a case when the resonances in p- and s-polarizations coincide [ 33 ]. However, it also does not provide any possibility for the dual-channel measurements.…”
Section: Introductionsupporting
confidence: 72%
“…Another possibility to increase the resonance Q-factor is to introduce a magnetic material in the sensing structure and to utilize the magneto-optical measurements of the transverse magneto-optical Kerr effect (TMOKE) instead of optical reflectance spectra [ 5 , 19 , 20 , 21 , 22 ]. The magneto-optical response can be enhanced with a variety of metamaterials [ 23 , 24 , 25 , 26 ], plasmonic coatings, dielectric nanostructures [ 27 , 28 , 29 ], and photonic crystals [ 30 , 31 , 32 , 33 ].…”
Section: Introductionmentioning
confidence: 99%
“…The refractive indices of the PMMA layer and glass are taken to be and , correspondingly. The dielectric permittivity tensor of Bi:YIG can be written in the form ( 3 ), where the diagonal element of the tensor 32 . The off-diagonal element g can be as high as at the saturation.…”
Section: Resultsmentioning
confidence: 99%
“…In traditional sensors, where the variations of the real part of the refractive index are measured, utilization of all-dielectric structures supporting high-quality quasisurface wave resonances instead of plasmonic structures was demonstrated to increase the signal-to-noise ratio and sensitivity by an order of magnitude [28,29]. Even higher sensitivity was demonstrated for magnetophotonic structures where the ultra-high quality-factor magneto-optical resonances were excited [29][30][31][32][33].…”
Section: Introductionmentioning
confidence: 99%