2018
DOI: 10.1093/jac/dky209
|View full text |Cite
|
Sign up to set email alerts
|

MALDI-TOF for the rapid detection of carbapenemase-producing Enterobacteriaceae: comparison of the commercialized MBT STAR®-Carba IVD Kit with two in-house MALDI-TOF techniques and the RAPIDEC® CARBA NP

Abstract: Overall, MALDI-TOF is a reliable technique for the rapid detection of CPE from cultured colonies. MBT STAR®-Carba IVD Kit, the only commercially available assay, could easily be implemented in a clinical microbiology laboratory if it is already equipped with a Microflex LT Biotyper mass spectrometer.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
37
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
9
1

Relationship

2
8

Authors

Journals

citations
Cited by 66 publications
(40 citation statements)
references
References 41 publications
2
37
0
1
Order By: Relevance
“…MALDI-TOF MS has an objective endpoint for result interpretation (179), but no standardized in-house protocol for carbapenemase detection is available (150,176,180). A commercially available MBT Star-Carba IVD kit (Bruker) was introduced very recently and was evaluated with 96.1% to 100% sensitivity and 89.0% to 99.9% specificity (181).…”
Section: Detection Of Carbapenemase Activitymentioning
confidence: 99%
“…MALDI-TOF MS has an objective endpoint for result interpretation (179), but no standardized in-house protocol for carbapenemase detection is available (150,176,180). A commercially available MBT Star-Carba IVD kit (Bruker) was introduced very recently and was evaluated with 96.1% to 100% sensitivity and 89.0% to 99.9% specificity (181).…”
Section: Detection Of Carbapenemase Activitymentioning
confidence: 99%
“…Moreover, the software enables the identification of the same target and assay of the same colonies being tested to detect carbapenemase activity. Dortet et al evaluated the commercialized MBT STAR-Carba IVD kit with two in-house MALDI-TOF MS methods and Rapidec Carba NP for detecting carbapenemase activity in 175 isolates, including 120 carbapenemase producers (132). Overall, all systems have very similar performances, with sensitivities ranging from 95% to 100% and specificities ranging from 98.2% to 100%.…”
Section: Ready-to-use Techniques In Clinical Practicementioning
confidence: 99%
“…The percent of agreement and the Cohen’s Kappa index value were calculated using the free software vassarStats ( ). The Kappa index value was interpreted as follows: ≤0, poor agreement; 0.01 to 0.20, slight agreement; 0.21 to 0.40, fair agreement; 0.41 to 0.60, moderate agreement; 0.61 to 0.80, substantial agreement; 0.81 to 1, almost perfect or perfect agreement [ 24 , 25 ].…”
Section: Methodsmentioning
confidence: 99%