2016
DOI: 10.1371/journal.pone.0148475
|View full text |Cite
|
Sign up to set email alerts
|

Manual Ventilation and Sustained Lung Inflation in an Experimental Model: Influence of Equipment Type and Operator’s Training

Abstract: AimTo compare the influence of devices for manual ventilation and individual experience on the applied respiratory mechanics and sustained lung inflation.MethodsA total of 114 instructors and non-instructors from the Neonatal Resuscitation Program of the Brazilian Society of Pediatrics participated in this study. Participants ventilated an intubated manikin. To evaluate respiratory mechanics and sustained lung inflation parameters, a direct comparison was made between the self-inflating bag and the T-shaped re… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
3
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 27 publications
0
3
0
Order By: Relevance
“…IL pallone va e vieni è generalmente monouso, il suo utilizzo è direttamente collegato all'intubazione e può essere usato solo da personale sanitario specificatamente addestrato [22] . A differenza dei dispositivi manuali, il rianimatore a T, essendo un dispositivo automatico, eroga ventilazioni più precise e prestanti in quanto i valori che vengono impostati a priori sul macchinario [11] garantiscono una ventilazione continua controllata [24] . In uno studio si evince che l'utilizzo di questo dispositivo per la rianimazione neonatale ha diminuito di 2/3 la mortalità e la morbilità dei neonati [13] .…”
Section: Discussioneunclassified
“…IL pallone va e vieni è generalmente monouso, il suo utilizzo è direttamente collegato all'intubazione e può essere usato solo da personale sanitario specificatamente addestrato [22] . A differenza dei dispositivi manuali, il rianimatore a T, essendo un dispositivo automatico, eroga ventilazioni più precise e prestanti in quanto i valori che vengono impostati a priori sul macchinario [11] garantiscono una ventilazione continua controllata [24] . In uno studio si evince che l'utilizzo di questo dispositivo per la rianimazione neonatale ha diminuito di 2/3 la mortalità e la morbilità dei neonati [13] .…”
Section: Discussioneunclassified
“…Barotrauma due to excessive peak inspiratory pressures is one of the contributing factors for the development of chronic lung injury (18). The choice of the ventilation device also contributes to the quality of manual ventilation, as applied tidal volumes and peak inspiratory pressures are higher when using a self-inflating bag compared to a T-piece system (19, 20). Therefore, it would have been of great interest to not only measure face mask leakage in our study, but also delivered tidal volume and peak inspiratory pressure; unfortunately this was not feasible, as these parameters are measured and displayed graphically, but are neither shown numerically on the computer screen nor saved for later analysis in the first version of the SMART system.…”
Section: Discussionmentioning
confidence: 99%
“…When the bag is compressed repeatedly by an operator's hand, it assists the patient with their breathing cycle [5]. These devices exist in various sizes that suit different ages and air volumes [6,7]. Manual respirators are meant to be used only during emergencies, given the inconvenience of requiring the constant implication of an operator that can become exhausted after protracted periods of time [8][9][10].…”
Section: Introductionmentioning
confidence: 99%