Mass Cytometry: Protocol for Daily Tuning and Running Cell Samples on a CyTOF Mass Cytometer

Abstract: In recent years, the rapid analysis of single cells has commonly been performed using flow cytometry and fluorescently-labeled antibodies. However, the issue of spectral overlap of fluorophore emissions has limited the number of simultaneous probes. In contrast, the new CyTOF mass cytometer by DVS Sciences couples a liquid single-cell introduction system to an ICP-MS.1 Rather than fluorophores, chelating polymers containing highly-enriched metal isotopes are coupled to antibodies or other specific probes. [2][… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
40
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
8
1

Relationship

3
6

Authors

Journals

citations
Cited by 40 publications
(40 citation statements)
references
References 8 publications
0
40
0
Order By: Relevance
“…The CyTOF ® instrument (version 1, Fluidigm) was started, tuned, and cleaned as described before on a daily basis (8), using tuning and wash solution (Fluidigm). Ultrapure argon was supplied by Praxair (Danbury, CT).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The CyTOF ® instrument (version 1, Fluidigm) was started, tuned, and cleaned as described before on a daily basis (8), using tuning and wash solution (Fluidigm). Ultrapure argon was supplied by Praxair (Danbury, CT).…”
Section: Methodsmentioning
confidence: 99%
“…For mass cytometry, variability in the machine performance (1) as well as in the sample preparation and staining procedure can be partially overcome by daily tuning of the CyTOF ® mass cytometer (8) and by using normalization beads (9). However, standardization of mass cytometry experiments that involve the comparison of multiple samples or stimulation conditions, should ideally based on exactly identical conditions for sample preparation and acquisition.…”
Section: Introductionmentioning
confidence: 99%
“…Stringent barcoding schemes and carefully monitoring and optimizing the concentration of the injected cell sample can eliminate the majority of doublets and help alleviate this problem (28). Variations in machine performance can also be addressed by standardized daily tuning procedures and metal-loaded beads for normalization of mass cytometry data (29,30). Currently, no computational tool exists for quantifying the quality of data and identifying potentially problematic samples.…”
Section: Developmental Trajectory Detection: Wanderlustmentioning
confidence: 99%
“…[14]. The length of the run will be dependent upon the volume of your sample: dilution with MilliQ water to ~1 million cells/mL is recommended for minimizing doublets as well as maximizing sample throughput ( see Note 10).…”
Section: Ics Staining Protocolmentioning