Advances in Mass Spectrometry 1959
DOI: 10.1016/b978-0-08-009210-2.50008-0
|View full text |Cite
|
Sign up to set email alerts
|

Mass Spectrometers and Mass Spectrographs Corrected for Image Defects

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

1968
1968
1996
1996

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 26 publications
(6 citation statements)
references
References 14 publications
0
6
0
Order By: Relevance
“…1. to form an image within the ESA with a parallel beam after the electric field [8]; 2. to use two electrostatic analyzers with an image formed between the two electric sectors [9]; and 3. to use an electrostatic quadrupole lens. The exit focal point of the ESA coincides with the focal point of the quadrupole such that the ion beam is parallel after quadrupole element [10].…”
Section: Normal System Where the Ion Beam Is Parallel Before The Magnetmentioning
confidence: 99%
“…1. to form an image within the ESA with a parallel beam after the electric field [8]; 2. to use two electrostatic analyzers with an image formed between the two electric sectors [9]; and 3. to use an electrostatic quadrupole lens. The exit focal point of the ESA coincides with the focal point of the quadrupole such that the ion beam is parallel after quadrupole element [10].…”
Section: Normal System Where the Ion Beam Is Parallel Before The Magnetmentioning
confidence: 99%
“…Choosing a curved virtual boundary will allow some formulas to be simplified, if a suitable curvature radius p is taken. On the other hand, this results in no additional problems, for the focusing features of curved boundary homogeneous sector fields were fully investigated by Hintenberger and Konig (1959). The equations of motion of the charged particle in the ideal field are Hereafter crossed quantities will apply to the motion in the ideal field.…”
Section: The Equations Of Motionmentioning
confidence: 99%
“…When an ion leaving the source has a certain angular divergence a, and at the same time differs from the mean velocity by a fraction /3, the deflection in the y direction after passing through the field is given by (Hintenberger and Konig 1959)…”
Section: Aberrationsmentioning
confidence: 99%
“…The ion optics of mass spectrometers have been studied by several workers, in particular Herzog (1934) and Hintenberger and Konig (1957). Ewald and Liebl(l955) have extended the study of the electrostatic field analyser to the toroidal field configuration, of which the cylindrical condenser used most often is a special case.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation