High‐Throughput Screening in Heterogeneous Catalysis 2004
DOI: 10.1002/3527604103.ch2
|View full text |Cite
|
Sign up to set email alerts
|

Mastering the Challenges of Catalyst Screening in High‐Throughput Experimentation for Heterogeneously Catalyzed Gas‐Phase Reactions

Abstract: For Abstract see ChemInform Abstract in Full Text.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2008
2008
2019
2019

Publication Types

Select...
6
3

Relationship

3
6

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 0 publications
0
4
0
Order By: Relevance
“…All experiments were carried out at ambient pressure ( P = 1 bar), whereas temperature ( T ), gas hourly space velocity (GHSV), and amount of ethyl chloride (EC) promoter in the gas feed were varied (230–350 °C, 1000–2000 h –1 , 0–4.5 ppm, respectively). Gas product analysis was performed via gas chromatography (GC) and mass spectrometry (MS) in a manner analogous to the procedures published elsewhere. All values given for conversion and selectivity were based on full carbon balances and augmented by the use of internal nonreactive standards (in this case methane and argon). Qualitative analysis and unambiguous identification of the components was ensured via mass-spectrometric analysis.…”
Section: Methodsmentioning
confidence: 99%
“…All experiments were carried out at ambient pressure ( P = 1 bar), whereas temperature ( T ), gas hourly space velocity (GHSV), and amount of ethyl chloride (EC) promoter in the gas feed were varied (230–350 °C, 1000–2000 h –1 , 0–4.5 ppm, respectively). Gas product analysis was performed via gas chromatography (GC) and mass spectrometry (MS) in a manner analogous to the procedures published elsewhere. All values given for conversion and selectivity were based on full carbon balances and augmented by the use of internal nonreactive standards (in this case methane and argon). Qualitative analysis and unambiguous identification of the components was ensured via mass-spectrometric analysis.…”
Section: Methodsmentioning
confidence: 99%
“…All experiments were performed at ambient pressure, whereas temperature (T), gas hourly space velocity (GHSV) and amount of ethyl chloride (EC) promoter in the gas feed were varied (230-350°C, 1000-2000 h -1 , 0-4.5 ppm, respectively). Gas chromatography (GC) and mass spectrometry (MS) were used for gas product analysis [41].…”
Section: Methodsmentioning
confidence: 99%
“…We select here, somewhat arbitrarily, HTE studies published early in 2014, so immediately prior to this conference. HTE has been applied with some success to the discovery and development of both homogeneous and heterogeneous catalysts [4][5][6][7][8][9][10][11][12][13][14][15][16]. As several recent examples are also discussed elsewhere in this volume, we look here to examples from other fields.…”
Section: Recent Examples In Materials For Energy Applicationsmentioning
confidence: 99%