2015
DOI: 10.1016/j.enconman.2015.05.053
|View full text |Cite
|
Sign up to set email alerts
|

Matching indices taking the dynamic hybrid electrical and thermal grids information into account for the decision-making of nZEB on-site renewable energy systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 24 publications
(8 citation statements)
references
References 23 publications
0
8
0
Order By: Relevance
“…Even if load-grid match is of increased importance [12,13,23,24], this does not constitute the main research issue of this paper. Whenever other energy carriers are used besides electricity, it is noteworthy that even if D = E, the electricity generation can be higher than the energy used and, therefore, the remaining is exported.…”
Section: Insert Table 3 Herementioning
confidence: 93%
“…Even if load-grid match is of increased importance [12,13,23,24], this does not constitute the main research issue of this paper. Whenever other energy carriers are used besides electricity, it is noteworthy that even if D = E, the electricity generation can be higher than the energy used and, therefore, the remaining is exported.…”
Section: Insert Table 3 Herementioning
confidence: 93%
“…Correspondingly, due to the IoE the national power grid may serve as 'virtual energy storage' to help single prosumers to obtain a zero-energy balance. The information and data to be collected via the IoE may contain several recorded, instantaneous or forecasted data items with various resolutions and accuracies, including variables and parameters such as the dynamic frequency or the dynamic import/export tariffs [46].…”
Section: (Insert Table 2 Around Here)31 Evolution Of Energy Supply Chainmentioning
confidence: 99%
“…to the building energy management system (EMS) controller to visualise and update the initial conditions for the next optimisation routine. This technique is applied in this chapter to test the proposed 39 models in real-time. Section 4.1 considers an electrical storage and photovoltaic panels when implementing the HIL test.…”
Section: Validation Of the Proposed Models Via Hardware-in-the-loop Tmentioning
confidence: 99%
“…Figure 5.1 shows the general principle of the explained energy matching indices. [38,39,40] The objective function (5.1) is applied in four case studies using the following adjustments.…”
Section: Microgrid Model Expanded To a Calendar Yearmentioning
confidence: 99%