1998
DOI: 10.1002/(sici)1097-0231(19980430)12:8<413::aid-rcm175>3.0.co;2-c
|View full text |Cite
|
Sign up to set email alerts
|

Matrix-assisted laser desorption/ionization for short tandem repeat loci

Abstract: Matrix-assisted laser desorption/ionization was used for the detection of four base short tandem repeats (STR) for clinical samples using a time-of-flight mass spectrometer. Since STR plays an important role in genetic disease and human identification, this work indicates that laser desorption mass spectrometry has the potential to achieve rapid DNA typing for both forensic applications and genetic disease diagnosis.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
19
0

Year Published

1999
1999
2011
2011

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 25 publications
(19 citation statements)
references
References 29 publications
0
19
0
Order By: Relevance
“…To date, Tang et al [5] and Liu et al [6] have reported the analysis of PCR products ϳ500 to 600 bases using UV-MALDI (at 337/355 nm), and Hillenkamp and co-workers extended the upper limit of DNA and RNA analyses up to ϳ2180 bases using IR-MALDI [7]. Applications such as analyzing short tandem repeats [8], gene-defect diseases [9 -11], and genotyping of single nucleotide polymorphisms [12] have been attempted. Despite these successes, oligonucleotide analysis by MALDI-MS has been limited primarily by the low ion abundances of larger oligonucleotides.…”
mentioning
confidence: 99%
“…To date, Tang et al [5] and Liu et al [6] have reported the analysis of PCR products ϳ500 to 600 bases using UV-MALDI (at 337/355 nm), and Hillenkamp and co-workers extended the upper limit of DNA and RNA analyses up to ϳ2180 bases using IR-MALDI [7]. Applications such as analyzing short tandem repeats [8], gene-defect diseases [9 -11], and genotyping of single nucleotide polymorphisms [12] have been attempted. Despite these successes, oligonucleotide analysis by MALDI-MS has been limited primarily by the low ion abundances of larger oligonucleotides.…”
mentioning
confidence: 99%
“…Indeed, there is no need for internal standards and allelic ladders as the actual mass of a DNA molecule is determined by MALDI-TOF method. Several researchers have reported progress in forensic STR analysis made by MALDI-TOF [80][81][82][83][84]. Ross and Belgrader [80] have reported a successful analysis of STR loci (COL1A, TPO1 and TPOX) present in subpicomole amounts.…”
Section: Maldi-tof-mass Spectrometrymentioning
confidence: 99%
“…Principally, mass spectrometric sequencing is based on the measurement of characteristic mass differences between sequence ladders. These informative ladders can either be produced prior to the mass spectrometric analysis via chemical or enzymatic reactions [11][12][13][14][15][16][17][18][19][20][21] or in the course of tandem mass spectrometric experiments via gas-phase fragmentation of oligonucleotide ions [22][23][24][25][26][27][28][29][30][31][32]. The principles of tandem mass spectrometry (MS/MS) of oligonucleotides have been extensively studied and reviewed [33].…”
Section: Introductionmentioning
confidence: 99%