Matrix effects on the multi-collector inductively coupled plasma mass spectrometric analysis of high-precision cadmium and zinc isotope ratios

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

6
61
0

Year Published

2009
2009
2017
2017

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 74 publications
(67 citation statements)
references
References 38 publications
6
61
0
Order By: Relevance
“…In addition, sample matrix effects are not expected given the consistent offset in both natural samples and pure Mo standards towards erroneously light isotopic compositions. Therefore, we conclude that this is a result of a nonspectral column matrix effect as has been reported elsewhere [38,41], which SSB and external normalization procedures fail to correct. This effect highlights a limitation of SSB and external normalization which is overcome by the adoption of a double-spike.…”
Section: Evaluation Of Column Isotope Effectsmentioning
confidence: 73%
See 2 more Smart Citations
“…In addition, sample matrix effects are not expected given the consistent offset in both natural samples and pure Mo standards towards erroneously light isotopic compositions. Therefore, we conclude that this is a result of a nonspectral column matrix effect as has been reported elsewhere [38,41], which SSB and external normalization procedures fail to correct. This effect highlights a limitation of SSB and external normalization which is overcome by the adoption of a double-spike.…”
Section: Evaluation Of Column Isotope Effectsmentioning
confidence: 73%
“…Molybdenum recoveries for two separate replicates of the USGS reference material BCR-2 using this protocol yielded 94 % as measured using ICP-MS (Agilent 7700x, Agilent Technologies, Santa Clara, CA, USA). In addition, this procedure provides quantitative separations of Zn and Cd in a single pass through the column [38,39], allowing for rapid throughput of multiple isotope systems (Mo, Zn, Cd). Elution curves and further details regarding the anion exchange chemistry protocol are available in Fig.…”
Section: Double-spike and Standard Calibration Verificationmentioning
confidence: 99%
See 1 more Smart Citation
“…Previously, ID was used in conjunction with thermal ionization. Later on, it was also implemented with ICP-MS. ID provides advantages over traditional calibration because the calculated isotope ratios, and hence the analytical results, obtained by means of ID-ICP-MS do not depend on instrumental instabilities and possible matrix effects [31][32][33]. Thus, highly accurate measurements can be performed, and the ID-MS technique may be regarded as one of definitive analytical methods.…”
Section: Isotope Dilutionmentioning
confidence: 99%
“…Metallic elements and residual resin-derived organic compounds lead to inaccurate Cd isotope results. 32 Pallavicicini et al 20 suggest ashing of organic-rich matrices. Wei et al 5,6 removed the organic matter of plants by HClO4.…”
Section: Introductionmentioning
confidence: 99%