2019
DOI: 10.1016/j.sab.2018.11.009
|View full text |Cite
|
Sign up to set email alerts
|

Matrix separation of Sr and Pb for isotopic ratio analysis of Ca-rich samples via an automated simultaneous separation procedure

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
9
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(9 citation statements)
references
References 30 publications
0
9
0
Order By: Relevance
“…The plates were stored in polyethylene zip bags until further analysis. Measurements of elemental content and 87 Sr/ 86 Sr isotope ratios were performed consecutively in parallel on small flat areas of the upper side of the otoliths for a length of 150 µm for elemental content and 450 µm for 87 Sr/ 86 Sr isotope ratios using a Sr/ 86 Sr isotope ratios have been determined in several studies for FEBS-1 (Yang et al, 2011;Zimmermann et al, 2019) and NIST SRM 1400 (Romaniello et al, 2015;Zimmermann et al, 2019). Data reduction was done according to established procedures (Irrgeher et al, 2016;Prohaska et al, 2016;Retzmann et al, 2019).…”
Section: Otolith Preparation and Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…The plates were stored in polyethylene zip bags until further analysis. Measurements of elemental content and 87 Sr/ 86 Sr isotope ratios were performed consecutively in parallel on small flat areas of the upper side of the otoliths for a length of 150 µm for elemental content and 450 µm for 87 Sr/ 86 Sr isotope ratios using a Sr/ 86 Sr isotope ratios have been determined in several studies for FEBS-1 (Yang et al, 2011;Zimmermann et al, 2019) and NIST SRM 1400 (Romaniello et al, 2015;Zimmermann et al, 2019). Data reduction was done according to established procedures (Irrgeher et al, 2016;Prohaska et al, 2016;Retzmann et al, 2019).…”
Section: Otolith Preparation and Analysismentioning
confidence: 99%
“…SLRS-5 river water certified reference material (NRC, Canada) was used for method validation along with all sample preparation steps. Elemental ratios are elemental amount ratios.Prior to 87 Sr/ 86 Sr isotope ratio measurements, Sr/matrix separation using a Sr-specific extraction resin (Sr Spec Resin, Triskem, Bruz, France) was performed to remove the isobaric interferences of 87 Rb on 87 Sr(Horsky et al, 2016) as well as Ca-based polyatomic interferences that form in the plasma and potentially occur on all nominal Sr isotope masses(Zimmermann et al, 2019). The 87 Sr/ 86 Sr isotope ratios of the water samples were measured with a MC ICP-MS instrument (Nu Plasma HR, Nu Instruments, Wrexham, UK).…”
mentioning
confidence: 99%
“…Following the results of the successful quantification during online matrix separation, an optimized Ca/matrix separation procedure is proposed in Table 3 previous studies [22,23,27] should be considered to remove remaining REEs (e.g. Y and U, see Supplementary Table 3) from the DGA Resin.…”
Section: Optimized Ca/matrix Separationmentioning
confidence: 99%
“…0.5 cm 3 or 1 cm 3 ) are collected during incremental elution and analyzed for their elemental composition, leading to a elution profile (see e.g. [22,23]). Online analysis of analyte/matrix separation provides a powerful alternative to batch separation.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation