2012
DOI: 10.5007/1980-0037.2012v14n3p264
|View full text |Cite
|
Sign up to set email alerts
|

Máximo estado estável de lactato estimado por diferentes métodos de determinação

Abstract: Maximal lactate steady state estimated by different methods of anaerobic threshold Máximo estado estável de lactato estimado por diferentes métodos de determinação do limiar anaeróbio

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 25 publications
0
3
0
Order By: Relevance
“…Another fact may be just the recruitment of male runners and the need to perform a MIRT. In addition, MLSS was not used as a gold standard, but LT 2 had a good approximation of MLSS in runners [30]. Therefore, it is suggested to carry out studies with different characteristics of samples, such as gender, age, and levels of training.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Another fact may be just the recruitment of male runners and the need to perform a MIRT. In addition, MLSS was not used as a gold standard, but LT 2 had a good approximation of MLSS in runners [30]. Therefore, it is suggested to carry out studies with different characteristics of samples, such as gender, age, and levels of training.…”
Section: Discussionmentioning
confidence: 99%
“…AnT) was determined as the running speed at 1.5 mmol·L −1 above LT 1 (Figure 1) [29]. The LT 1 and LT 2 derived from the Dickhuth et al's [29] methods were used as criterium measures, because LT 1 has a high correlation with MLSS [7], and LT 2 (+1.5 mmol·L −1 ) was used because it showed a high concordance with MLSS in runners during the MIRT with stages of 3 min [30].…”
Section: Methodsmentioning
confidence: 99%
“…Ventilatory thresholds (VT) [35] and respiratory compensation points (RCP) [36] are normally calculated from oxygen uptake data. There is also a broad range of lactate thresholds (LT), which respond to different concepts and can be obtained through several different testing protocols: individual anaerobic threshold (IAT) [37], maximal lactate steady state (MLSS) [38], fixed blood lactate concentrations of 2 and 4 mmol/L, initial rises of 1 mmol/L, Dmax [39], and modified Dmax [40] methods.…”
Section: Relationship Between Functional Threshold Power and Laboratomentioning
confidence: 99%