2008
DOI: 10.1016/j.radmeas.2007.11.032
|View full text |Cite
|
Sign up to set email alerts
|

MCz diode response as a high-dose gamma radiation dosimeter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

1
5
0
3

Year Published

2011
2011
2018
2018

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 17 publications
(9 citation statements)
references
References 2 publications
1
5
0
3
Order By: Relevance
“…This scenario has changed with the development of rad-hard diodes based on magnetic Czockralski (MCz), standard and oxygen-enriched float zone (FZ) silicon substrates [3] which will be used in the tracking system of future colliding beam experiments [4]. The dosimetric characteristics of some rad-hard devices have been investigated in our group in both radiation processing and clinical electron beam dosimetry [5,6]. Despite of the higher radiation tolerance of these devices, our results have still shown a sensitivity decay with the dose, attributed to the reduction of the minority carrier lifetime/diffusion length as a function of the dose.…”
Section: Introductionmentioning
confidence: 99%
“…This scenario has changed with the development of rad-hard diodes based on magnetic Czockralski (MCz), standard and oxygen-enriched float zone (FZ) silicon substrates [3] which will be used in the tracking system of future colliding beam experiments [4]. The dosimetric characteristics of some rad-hard devices have been investigated in our group in both radiation processing and clinical electron beam dosimetry [5,6]. Despite of the higher radiation tolerance of these devices, our results have still shown a sensitivity decay with the dose, attributed to the reduction of the minority carrier lifetime/diffusion length as a function of the dose.…”
Section: Introductionmentioning
confidence: 99%
“…In the last years, the development of radiation tolerant silicon detectors for High Energy Physics experiments has overcome this drawback. The dosimetric characteristics of two types of these rad-hard devices, produced by the Standard Float Zone (FZ) and the Magnetic Czochralski (MCz) techniques, have been investigated in our group in both radiation processing [4] and clinical electron beam dosimetry. In this work we present the preliminary results obtained with rad-hard Standard Float Zone (FZ) and Magnetic Czochralski (MCz) silicon diodes as on-line clinical electron beams dosimeter.…”
Section: Introductionmentioning
confidence: 99%
“…Um dos mais importantes resultados, obtidos por estes estudos, mostrou que a presença de oxigênio, em concentrações elevadas (10 17 cm -3 ), na estrutura dos detectores de Si, aumenta a tolerância aos danos de radiação responsáveis pelas alterações da tensão de depleção total destes dispositivos [18][19][20] [11,12,[19][20][21][22][23].…”
Section: Introductionunclassified