MDP-based universal adhesive system irradiated with Er,CR:YSGG: Analysis of its performance up to 6 months

Abstract: This study aimed to analyze the interaction of a MDP-based universal dentin bonding system (DBS) with Er, Cr: YSGG laser irradiation, measuring the microtensile bond strength to dentin over a six-month period. The experimental design involved three factors: DBS (Adper Scotchbond Universal; Clearfil SE Bond, Adper Scotchbond Multipurpose and Adper Single Bond 2), laser (Control and Er, Cr: YSGG), and time (initial-7 days and 6 months). Eighty dentin samples from molars were prepared (n=10) with laser irradiatio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

1
0
0
1

Year Published

2022
2022
2022
2022

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 38 publications
1
0
0
1
Order By: Relevance
“…Irradiated groups were affected negatively, with exception SU-L that did not present a significant drop in the MS values. These data corroborate the work of Zabeu et al,2021 however in the period of 6 months. Drop in bond strength values over time are expected (Yoshida et al, 2012) regardless of the adhesive type, however the laser irradiation promoted a significantly greater drop.…”
Section: Resultssupporting
confidence: 91%
“…Irradiated groups were affected negatively, with exception SU-L that did not present a significant drop in the MS values. These data corroborate the work of Zabeu et al,2021 however in the period of 6 months. Drop in bond strength values over time are expected (Yoshida et al, 2012) regardless of the adhesive type, however the laser irradiation promoted a significantly greater drop.…”
Section: Resultssupporting
confidence: 91%
“…Los resultados del presente estudio muestran que la media de la resistencia adhesiva microtraccional del sistema adhesivo de sexta generación presenta una media de 23.29 MPa y del sistema adhesivo de octava generación reportó una media de 18.75 MPa, discrepando con los resultados del estudio de Costa y Cols., 10 Cols., 20 evaluaron la interacción de un sistema de unión universal en dentina (DBS) basado en metacriloiloxidocil dihidrógeno fosfato (MDP) con Er, Cr:…”