2017
DOI: 10.1111/aos.13517
|View full text |Cite
|
Sign up to set email alerts
|

Measurement centration and zone diameter in anterior, posterior and total corneal astigmatism in keratoconus

Abstract: Centration and measurement zone diameter have great impacts on the astigmatic values in KC. A small pupil-centred measurement zone should be considered when evaluating the astigmatism in KC.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
3
0
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 29 publications
0
3
0
1
Order By: Relevance
“…Newer technologies, such as Scheimpflug camera imaging (Koch et al 2012;Savini et al 2014;Tonn et al 2015;Naeser et al 2017), optical coherence tomography (Ueno et al 2014) and specular reflections (Klijn et al 2016), measure keratometric astigmatism (KA) and posterior corneal astigmatism (PCA) separately. These methods may also provide a total corneal astigmatism (TCA), based on Snell 0 s law (Koch et al 2012;Savini et al 2014;Tonn et al 2015;Klijn et al 2016;Fredriksson & Behndig 2017;Nae et al 2017).…”
Section: Introductionmentioning
confidence: 99%
“…Newer technologies, such as Scheimpflug camera imaging (Koch et al 2012;Savini et al 2014;Tonn et al 2015;Naeser et al 2017), optical coherence tomography (Ueno et al 2014) and specular reflections (Klijn et al 2016), measure keratometric astigmatism (KA) and posterior corneal astigmatism (PCA) separately. These methods may also provide a total corneal astigmatism (TCA), based on Snell 0 s law (Koch et al 2012;Savini et al 2014;Tonn et al 2015;Klijn et al 2016;Fredriksson & Behndig 2017;Nae et al 2017).…”
Section: Introductionmentioning
confidence: 99%
“…The corneal apex is found as a better reference center for toric IOL surgical planning according to our data. Choosing the inappropriate reference center may reduce the prediction accuracy, especially when there is a certain distance between the two reference centers (19). Previously, some studies recommended the pupil center as the reference center in this context, because the researchers considered that the entrance pupil controls what the patient sees (20,21).…”
Section: Discussionmentioning
confidence: 99%
“…(4,(16)(17)(18)(19)(20)(21) Com relação às aberrações de alta ordem, elas podem ser rastreadas por meio do OPD Scan, o qual auxilia o oftalmologista a medir as irregularidades ópticas, dentre elas, as da córnea. (2,3,4,10,(22)(23)(24)(25)(26)(27)(28)(29)(30)(31)(32)(33)(34) Já a classificação ABCD de Belin-Ambrósio é uma das mais utilizadas como critério diagnóstico do ceratocone. (9)(10)(11)(12)14,(25)(26)(27) Diante disso, destaca-se a importância do diagnóstico do ceratocone o mais precocemente possível, para que sejam adotadas estratégias de tratamento menos invasivas e para melhorar o prognóstico da população em geral.…”
Section: Introductionunclassified