Measurement‐guided volumetric dose reconstruction for helical tomotherapy

Abstract: It was previously demonstrated that dose delivered by a conventional linear accelerator using IMRT or VMAT can be reconstructed — on patient or phantom datasets — using helical diode array measurements and a technique called planned dose perturbation (PDP). This allows meaningful and intuitive analysis of the agreement between the planned and delivered dose, including direct comparison of the dose‐volume histograms. While conceptually similar to modulated arc techniques, helical tomotherapy introduces signific… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 6 publications
(7 citation statements)
references
References 39 publications
0
7
0
Order By: Relevance
“…These systems utilize the measured dose with conventional verification QA tools and reconstruct the dose to the patient to assess the clinical impact. These dose reconstruction algorithms contain significant approximations and their limitations have been demonstrated by recent studies …”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…These systems utilize the measured dose with conventional verification QA tools and reconstruct the dose to the patient to assess the clinical impact. These dose reconstruction algorithms contain significant approximations and their limitations have been demonstrated by recent studies …”
Section: Introductionmentioning
confidence: 99%
“…These dose reconstruction algorithms contain significant approximations and their limitations have been demonstrated by recent studies. 20 HT is a dedicated IMRT system with an on-board megavoltage computed tomography (MVCT) imaging system. The on board detector (OBD) consists of an arc-shaped xenon detector array positioned opposite the linear accelerator on a rotating slip-ring gantry.…”
Section: Introductionmentioning
confidence: 99%
“…Similarly to the previously mentioned audits for advanced treatment techniques, 3D dose reconstruction has not yet been applied in Tomotherapy auditing. CT data sets for planning and phantom-based 3D dosimetry have been investigated and validated [72] . The volumetric dose reconstruction based on helical diode array measurements is generally similar to the approach in rotational IMRT [67] , but the calculation algorithm is different due to the conceptual differences between helical Tomotherapy and VMAT.…”
Section: Phantom Based Methods For Dosimetry Auditsmentioning
confidence: 99%
“…15,16 Devices with 2D arrays also have successful applications in helical Tomotherapy QA 17,18 despite the possible limitation due to its directional dependency. 19,20 The ArcCHECK (Sun Nuclear, Melbourne, FL, Australia), a cylindrical acrylic phantom with an array of spirally arranged diode detectors, has been found to be well suited for QA of VMAT, IMRT, and Tomotherapy, [21][22][23][24][25][26][27] since the cylindrical design of Arc-CHECK removes rotational dependence of the detectors.…”
Section: Introductionmentioning
confidence: 99%