Abstract:A high-temperature and high-pressure dual-capillary viscometer
was developed to measure the dynamic viscosity of liquid and supercritical
coal-based kerosene in the temperature range of 299.6–678.8
K and pressure range of 0.3–40.4 MPa. The extended relative
uncertainty of the measurement results ranged from 0.8–5% (confidence
factor k = 2). Using the differential of the pressure
drop across the capillary with flow rate in the viscosity derivation,
rather than the pressure drop directly, gave better experimenta… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.