Photosynthesis: From Light to Biosphere 1995
DOI: 10.1007/978-94-009-0173-5_1142
|View full text |Cite
|
Sign up to set email alerts
|

Measuring Fast Fluorescence Transients to Address Environmental Questions: The JIP-Test

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

4
337
0
17

Year Published

2011
2011
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 409 publications
(372 citation statements)
references
References 3 publications
4
337
0
17
Order By: Relevance
“…The assessment of the kinetics of fluorescence emission of chlorophyll a permits calculation of the fluorescence parameters which characterize the operation of the photosynthetic apparatus (Yusuf et al, 2010). This assessment can be described using the JIP test (Strasser and Strasser, 1995;Tsimilli-Michael and Strasser, 2008), quantifying the energy flow that passes by the photosystems and assessing the photosynthetic performance of plants (Strasser and Strasser, 1995;Strasser et al, 2004;Tsimilli-Michael and Strasser, 2008).…”
Section: Introductionmentioning
confidence: 99%
“…The assessment of the kinetics of fluorescence emission of chlorophyll a permits calculation of the fluorescence parameters which characterize the operation of the photosynthetic apparatus (Yusuf et al, 2010). This assessment can be described using the JIP test (Strasser and Strasser, 1995;Tsimilli-Michael and Strasser, 2008), quantifying the energy flow that passes by the photosystems and assessing the photosynthetic performance of plants (Strasser and Strasser, 1995;Strasser et al, 2004;Tsimilli-Michael and Strasser, 2008).…”
Section: Introductionmentioning
confidence: 99%
“…Detailed information can be obtained through fluorescence on the structure, energy distribution and function of the photosynthesis operation, especially for PSII (Strasser et al, 2000). But fluorescence data can be better interpreted using the assessor test, the JIP-Test (Strasser and Strasser, 1995). By using the non-modulated fluorimeter Strasser and Strasser (1995), an optimized interpretations of fast fluorescence kinetics (F 0 =50ms; Fj=2ms and Fi=30ms) that lie between the two extremes of the fluorescence intensity (F 0 =50µs and Fm = 300ms) can be obtained.…”
Section: Introductionmentioning
confidence: 99%
“…But fluorescence data can be better interpreted using the assessor test, the JIP-Test (Strasser and Strasser, 1995). By using the non-modulated fluorimeter Strasser and Strasser (1995), an optimized interpretations of fast fluorescence kinetics (F 0 =50ms; Fj=2ms and Fi=30ms) that lie between the two extremes of the fluorescence intensity (F 0 =50µs and Fm = 300ms) can be obtained. The JIP-Test is based on the theory of energy flow in biomembranes, which uses ratios to obtain variables that explain the energy flow through PS II (Strasser and Strasser, 1995).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Os resultados da cinética da fluorescência transiente foram tabulados com o programa PEA Plus para uma planilha eletrônica. A partir do teste JIP (Strasser & Strasser, 1995) …”
Section: Características Fotossintéticasunclassified