2015
DOI: 10.1364/boe.6.002840
|View full text |Cite
|
Sign up to set email alerts
|

Measuring oxygen saturation in retinal and choroidal circulations in rats using visible light optical coherence tomography angiography

Abstract: Visible light optical coherence tomography (vis-OCT) has demonstrated its capability of measuring vascular oxygen saturation (sO2) in vivo. Enhanced by OCT angiography, the signal from microvasculature can be further isolated and directly used for sO2 extraction. In this work, we extended the theoretical formulation for OCT angiography-based oximetry by incorporating the contribution from motion contrast enhancement. We presented a new method to eliminate the associated confounding variables due to blood flow.… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
88
1

Year Published

2015
2015
2024
2024

Publication Types

Select...
9
1

Relationship

7
3

Authors

Journals

citations
Cited by 53 publications
(90 citation statements)
references
References 42 publications
1
88
1
Order By: Relevance
“…The procedure for retinal oximetry and blood flow measurements with vis-OCT has been demonstrated and validated in rodent models (Chen, Yi & Zhang, 2015, Soetikno, et al, 2015, Yi, et al, 2015b, Yi et al, 2013). The MRO 2 of the inner retina was measured using vis-OCT during progressive systemic hypoxic challenge, where the inhaled oxygen content was progressively decreased (Yi et al, 2013).…”
Section: 2 Validation Of Metabolic Imaging With Vis-octmentioning
confidence: 99%
“…The procedure for retinal oximetry and blood flow measurements with vis-OCT has been demonstrated and validated in rodent models (Chen, Yi & Zhang, 2015, Soetikno, et al, 2015, Yi, et al, 2015b, Yi et al, 2013). The MRO 2 of the inner retina was measured using vis-OCT during progressive systemic hypoxic challenge, where the inhaled oxygen content was progressively decreased (Yi et al, 2013).…”
Section: 2 Validation Of Metabolic Imaging With Vis-octmentioning
confidence: 99%
“…Meanwhile, calculating intragroup decorrelation on complex OCT B-scans yielded OCT angiography. 19 The detailed steps to perform spectroscopic OCT analysis for sO 2 were previously documented. 12 Briefly, we adopted shorttime Fourier transform (STFT), which split the entire spectrum into equally spaced narrow bands in k-space.…”
Section: Data Processingmentioning
confidence: 99%
“…Although vis-OCT penetration is less than conventional OCT in the near infrared band, the choriocapillaris could still be detected. The field of view of angiography images was larger than previous reports of visible-light OCTA [30,60,61]. When imaging chicken embryo, the microvascular and a venous bifurcation were investigated and a laminar behavior was observed near a venous bifurcation.…”
Section: Discussionmentioning
confidence: 93%