Measuring stable carbon and nitrogen isotopes by IRMS and 14C by AMS on samples with masses in the microgram range: Performances of the system installed at CEDAD-University of Salento

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
9

Relationship

4
5

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 12 publications
0
7
0
Order By: Relevance
“…A fraction of the extracted collagen was separated from nine of the samples for the determination of the C:N ratio and for carbon and nitrogen stable isotope analyses which were performed by using an elemental analyzer (EA-Mod. Flash 2000 HT by Thermo) and an isotopic ratio mass spectrometry (IRMS) system (Delta V Plus by Thermo; Braione et al 2015;Maruccio et al 2017). The fraction selected for 14 C analysis was combusted to CO 2 in sealed quartz tubes with CuO and Silver wool and then reduced at 600°C to graphite with H 2 on Fe powder used as catalyst.…”
Section: Methodsmentioning
confidence: 99%
“…A fraction of the extracted collagen was separated from nine of the samples for the determination of the C:N ratio and for carbon and nitrogen stable isotope analyses which were performed by using an elemental analyzer (EA-Mod. Flash 2000 HT by Thermo) and an isotopic ratio mass spectrometry (IRMS) system (Delta V Plus by Thermo; Braione et al 2015;Maruccio et al 2017). The fraction selected for 14 C analysis was combusted to CO 2 in sealed quartz tubes with CuO and Silver wool and then reduced at 600°C to graphite with H 2 on Fe powder used as catalyst.…”
Section: Methodsmentioning
confidence: 99%
“…Integrated designs are also being developed to facilitate measurement of different quantities and parameters simultaneously from the same sample. This is already the case for combined elemental analyzer-isotope ratio mass spectrometry-AMS systems (EA-IRMS-AMS), which can measure carbon and nitrogen stable isotopes, concentration and radiocarbon age 353,354 .…”
Section: [H2] Measurement Techniquesmentioning
confidence: 99%
“…With this setup, we could demonstrate stable operating conditions and the possibility to analyze samples of mass as low as 10 μgC with uncertainty levels of 1% and with background levels of 5×10 –14 (Maruccio et al 2017).…”
Section: Methodsmentioning
confidence: 99%