2021
DOI: 10.14503/thij-21-7571
|View full text |Cite
|
Sign up to set email alerts
|

Mechanical Thrombectomy of Pulmonary Emboli With Use of the Indigo System and Lightning 12 Intelligent Aspiration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(7 citation statements)
references
References 5 publications
0
7
0
Order By: Relevance
“…The key innovations of the novel Lightning 12 system are the new CAT12 catheter, with a large 0.131'' lumen and angled tip for an additional circumferential sweep, and the lighting control unit with a pressure/flow sensor system and high-frequency valves. These innovations aim to efficiently regulate aspiration and prevent excessive blood loss [5]. Our case showed that CDMT with the use of the Lightning 12 system was well tolerated and effective.…”
mentioning
confidence: 71%
“…The key innovations of the novel Lightning 12 system are the new CAT12 catheter, with a large 0.131'' lumen and angled tip for an additional circumferential sweep, and the lighting control unit with a pressure/flow sensor system and high-frequency valves. These innovations aim to efficiently regulate aspiration and prevent excessive blood loss [5]. Our case showed that CDMT with the use of the Lightning 12 system was well tolerated and effective.…”
mentioning
confidence: 71%
“…Meanwhile, surgical embolectomy involves a sternotomy for pulmonary artery exposure and opening of the pulmonary artery (PA) for removal of the thrombus. 27 28 29 Fig. 1 shows an example of a PE diagnosed on CT PE.…”
Section: Discussionmentioning
confidence: 99%
“…However, in patients with absolute contraindications to pharmacologic thrombolysis, failed thrombolytic therapy, patent foramen ovale, or pregnancy, pulmonary embolectomy via an interventionalist or surgeon is indicated. 18,[27][28][29] The interventionalist can utilize various catheter devices that can break up/dissolve the blood clot or suction out the clot. These devices utilize a percutaneous approach and are advanced antegrade into the pulmonary artery.…”
Section: Prevention Of Pulmonary Embolismmentioning
confidence: 99%
“…Indigo CAT8 is an aspiration thrombectomy-based system that implements automatic suction through an 8 F catheter and uses a retractable separator that moves back and forth, facilitating thrombus fragmentation [ 19 ]. Indigo CAT12 has an improved algorithm that controls automatic valves, reducing blood loss and optimizing clot removal [ 20 ]. Cleaner XT TM is a 6 F rotational thrombectomy system, utilizing a sinuous-shaped radio-opaque wire that rotates at approximately 4000 rounds per minute, facilitating gentle mechanical declotting [ 21 ].…”
Section: Methodsmentioning
confidence: 99%