2020
DOI: 10.3390/en13061305
|View full text |Cite
|
Sign up to set email alerts
|

Membrane Capacitive Deionization for Cooling Water Intake Reduction in Thermal Power Plants: Lab to Pilot Scale Evaluation

Abstract: Cooling of thermal power stations requires large amounts of surface water and contributes to the increasing pressure on water resources. Water use efficiency of recirculating cooling towers (CT) is often kept low to prevent scaling. Partial desalination of CT feed water with membrane capacitive deionization (MDCI) can improve water quality but also results in additional water loss. A response surface methodology is presented in which optimal process conditions of the MCDI-CT system are determined in view of wa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 33 publications
0
3
0
Order By: Relevance
“…The program determines the model type based on the coefficient of determination R 2 and the significance of the Fcount. The type of polynomial model can also be observed from the sum of squares in the model order (Sequential Model Sum of Squares), lack of fit test, R 2 , and adjusted-R 2 [24]. A model is considered good when it has significant values for the response and insignificant values for the lack of fit test.…”
Section: Optimization Of Factor Combinations For Cr (Vi) Ion Adsorptionmentioning
confidence: 99%
“…The program determines the model type based on the coefficient of determination R 2 and the significance of the Fcount. The type of polynomial model can also be observed from the sum of squares in the model order (Sequential Model Sum of Squares), lack of fit test, R 2 , and adjusted-R 2 [24]. A model is considered good when it has significant values for the response and insignificant values for the lack of fit test.…”
Section: Optimization Of Factor Combinations For Cr (Vi) Ion Adsorptionmentioning
confidence: 99%
“…An experimental study has been carried out to investigate the efficiency of the wet cooling tower having diverse packing compaction using the artificial neural network and particle swarm optimization algorithm [8]. An analysis to reduce water intake for cooling towers used in thermal power plants as a pilot study [9]. Membrane capacitive deionization (MCDI) has been done in this study.…”
Section: Introductionmentioning
confidence: 99%
“…The optimization of CT operation with the use of membrane capacitive deionized water reduces water consumption and cost [26]. But, the research work related to minimization of feed and bleed operation concerning the operating and environmental condition is very few.…”
Section: Introductionmentioning
confidence: 99%