2020
DOI: 10.1016/j.jece.2020.104018
|View full text |Cite
|
Sign up to set email alerts
|

Membrane fouling suppression using intermittent electric current with low exposure time in a sequencing batch membrane bioreactor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
5
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 27 publications
(6 citation statements)
references
References 46 publications
1
5
0
Order By: Relevance
“…Hou et al [47] obtained partial mitigation of the membrane fouling to approximately 0.42-0.53 × 10 11 m −1 h −1 by the application of a micro-electric field. Furthermore, Souza et al [48] reported that the application of electric field allowed the attenuation of the membrane fouling rate to 0.24 × 10 11 m −1 h −1 , which resulted comparable to the lowest values obtained in the present study although without using electric energy. Therefore, lowering the EPS content in the sludge by driving the conversion of the exogenous carbon toward PHA rather EPS resulted in a lower fouling tendency of the membrane.…”
Section: Evaluation Of Membrane Fouling Tendency and Mechanismssupporting
confidence: 86%
See 1 more Smart Citation
“…Hou et al [47] obtained partial mitigation of the membrane fouling to approximately 0.42-0.53 × 10 11 m −1 h −1 by the application of a micro-electric field. Furthermore, Souza et al [48] reported that the application of electric field allowed the attenuation of the membrane fouling rate to 0.24 × 10 11 m −1 h −1 , which resulted comparable to the lowest values obtained in the present study although without using electric energy. Therefore, lowering the EPS content in the sludge by driving the conversion of the exogenous carbon toward PHA rather EPS resulted in a lower fouling tendency of the membrane.…”
Section: Evaluation Of Membrane Fouling Tendency and Mechanismssupporting
confidence: 86%
“…The findings of this study suggested that operating with the activated sludge enriched in PHA storing microorganisms and by applying proper operating conditions that promote PHA production, involved a lower conversion of the organic carbon into EPS, which corresponded to a lower membrane-fouling tendency. Compared with other MBR operating under similar F/M, the EPS content in the mixed liquor in the present study was about 30–40% lower, on average [ 11 , 48 , 49 ]. Consequently, given the well-recognized role of the EPS in the membrane fouling, low content of such substances in the mixed liquor reduced the membrane-fouling tendency and did not lead to problems in membrane operation in the long term.…”
Section: Resultsmentioning
confidence: 47%
“…The literature thus offers much evidence that the affinity between solutes and membranes, described by parameters such as sorption and aggregation of solutes on membrane surfaces and into the membrane pores, is the dominant factor governing fouling. Accordingly, approaches based on tailoring membrane surface properties have been suggested to minimize fouling [ 15 , 16 ]. Generally, hydrophilic membranes present improved anti-fouling and flux recovery properties.…”
Section: Introductionmentioning
confidence: 99%
“…The TMP measurements revealed an increase during the operational period, which is consistent with previous studies 16,17 . These studies have reported that membrane fouling can lead to a decline in permeate flux or an increase in TMP, depending on the operational mode 18 .…”
Section: Effect Of Wastewater Temperature On the Performance Of A Des...mentioning
confidence: 99%