2015
DOI: 10.1007/s12668-015-0179-4
|View full text |Cite
|
Sign up to set email alerts
|

Memristive Biosensors for PSA-IgM Detection

Abstract: Prostate cancer is the most common cancer among men except for skin cancer, and the detection at early stages is crucial. In the present work, nanofabricated memristive biosensors are subjected to surface bio-modification targeting at prostate-specific antigen (PSA) IgM detection. The electrical response of the nanofabricated devices examined before and after the bio-modification achieves a label-free detection for three biomarker concentrations. The presence of biomolecules linked to the surface of the nanost… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 15 publications
(10 citation statements)
references
References 26 publications
0
10
0
Order By: Relevance
“…Carrara et al have been working for a while on the fabrication of memristors with silicon nanowires [84] and their further implementation for biosensing purposes [85,86]. A combination of the Complementary Metal Oxide Semiconductor (CMOS) processing technique and photolithography was used to develop poly-crystalline silicon nanowires that exhibited memristive behaviour.…”
Section: Utilisation Of Silicon For Biomedical Applicationsmentioning
confidence: 99%
“…Carrara et al have been working for a while on the fabrication of memristors with silicon nanowires [84] and their further implementation for biosensing purposes [85,86]. A combination of the Complementary Metal Oxide Semiconductor (CMOS) processing technique and photolithography was used to develop poly-crystalline silicon nanowires that exhibited memristive behaviour.…”
Section: Utilisation Of Silicon For Biomedical Applicationsmentioning
confidence: 99%
“…Memristive silicon-wire devices are fabricated for this work through a top-down fabrication process utilizing Electron Beam (E-Beam) lithography and Deep Reactive Ion Etching (DRIE) processes [30]. Fig.…”
Section: Memristive Sensormentioning
confidence: 99%
“…The (1 × 1) cm 2 chip consisting of memristive devices, is thereafter wire-bonded on a specially designed chip-holder that can be easily plugged using board-to-board connectors to the main PCB allowing a flexible and robust sensing procedure. Further details are present in [30], [25].…”
Section: Memristive Sensormentioning
confidence: 99%
“…Memristive Si-NW devices were obtained through a top-down nanofabrication process as described by Tzouvadaki et al 21 The 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 12 incubated overnight in 2 μM of biotinylated anti-PSA DNA aptamer solution in PBS at 4 °C in a humidity chamber. Prior to use, biotinylated DNA aptamers were activated at 95 °C for 10 min before being gradually cooled to room temperature for 30 min 23 .…”
Section: Surface Modificationmentioning
confidence: 99%