1995
DOI: 10.1016/s0883-5403(05)80111-1
|View full text |Cite
|
Sign up to set email alerts
|

Mennen plate fixation for fracture of the femoral shaft with ipsilateral total hip and knee arthroplasties

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
14
0
1

Year Published

1998
1998
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 51 publications
(15 citation statements)
references
References 6 publications
0
14
0
1
Order By: Relevance
“…For this reason, the solution to the problem "femoral fracture in hip arthroplasty" is not completely resolved with regard to classification and treatment. Open reduction and internal fixation with cerclage, plates and screws, plates, cerclage and screws; retrograde femoral nailing (type C fractures); and one-stage or two-stage revision arthroplasty (with or without bone grafting) have been proposed [20][21][22][23][24][25][26][27][33][34][35].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…For this reason, the solution to the problem "femoral fracture in hip arthroplasty" is not completely resolved with regard to classification and treatment. Open reduction and internal fixation with cerclage, plates and screws, plates, cerclage and screws; retrograde femoral nailing (type C fractures); and one-stage or two-stage revision arthroplasty (with or without bone grafting) have been proposed [20][21][22][23][24][25][26][27][33][34][35].…”
Section: Discussionmentioning
confidence: 99%
“…Many types of treatments have been proposed, both non-surgical [18,19] and surgical [20][21][22][23][24][25][26][27]. However, the age of these patients, the longer time of bed rest, and the higher incidence of complications using non-surgical treatment [1,3,17,[28][29][30] have guided many clinicians, including ourselves, to use non-surgical treatment only in few selected cases.…”
Section: Introductionmentioning
confidence: 99%
“…In the first, failure of the plate occurred in 2 cases out of 6. Another report described the use of the Mennen plate for a fracture above a knee arthroplasty in the femur of a patient with rheumatoid arthritis, and union was achieved [3]. In another report where the plate had been used on 4 patients, failure of the plate had occurred in one.…”
Section: Discusionmentioning
confidence: 99%
“…In an effort to provide improved screw fixation, cortical strut allografts can be used as a way of anchoring the screw to the opposite cortex, thus "sandwiching" the host shaft. The allograft struts provide stability to the fracture site, and they can incorporate [4] and ultimately increase the femoral or humeral bone stock [1,7,9,13,14,21]. Similar techniques have been described for periprosthetic fractures, hip revisions, or complex non-unions [5,11,12,14,19,22].…”
Section: Introductionmentioning
confidence: 99%