Mesowestern Blot: Simultaneous Analysis of Hundreds of Submicroliter Lysates

Abstract: Western blotting is a widely used technique for molecular-weight-resolved analysis of proteins and their posttranslational modifications, but high-throughput implementations of the standard slab gel arrangement are scarce. The previously developed Microwestern requires a piezoelectric pipetting instrument, which is not available for many labs. Here, we report the Mesowestern blot, which uses a 3D-printable gel casting mold to enable high-throughput Western blotting without piezoelectric pipetting and is compat… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(4 citation statements)
references
References 43 publications
0
4
0
Order By: Relevance
“…This would allow for reliable detection (~90% confidence, ~80% power) of ~1.5 fold changes with triplicate measurements. Previous western blotting work reports CV from 15% to 70% (or more) 13,[22][23][24][25] , so this value is typical or even low for western blots. Importantly, the CV reported for this particular 96-well western is artificially high since there is by definition no loading control, which is generally known to improve CV 21 by about a factor of 1.25 13 , down to ~12-20% 24,25 .…”
Section: Recombinant Protein Experimentsmentioning
confidence: 87%
See 3 more Smart Citations
“…This would allow for reliable detection (~90% confidence, ~80% power) of ~1.5 fold changes with triplicate measurements. Previous western blotting work reports CV from 15% to 70% (or more) 13,[22][23][24][25] , so this value is typical or even low for western blots. Importantly, the CV reported for this particular 96-well western is artificially high since there is by definition no loading control, which is generally known to improve CV 21 by about a factor of 1.25 13 , down to ~12-20% 24,25 .…”
Section: Recombinant Protein Experimentsmentioning
confidence: 87%
“…Previous western blotting work reports CV from 15% to 70% (or more) 13,[22][23][24][25] , so this value is typical or even low for western blots. Importantly, the CV reported for this particular 96-well western is artificially high since there is by definition no loading control, which is generally known to improve CV 21 by about a factor of 1.25 13 , down to ~12-20% 24,25 . Conveniently, one potential use of these 96-well blots is to include replication in the gel loading design to improve statistical performance.…”
Section: Recombinant Protein Experimentsmentioning
confidence: 87%
See 2 more Smart Citations