2009
DOI: 10.1016/j.jcms.2008.12.005
|View full text |Cite
|
Sign up to set email alerts
|

Method selection in craniofacial measurements: Advantages and disadvantages of 3D digitization method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
58
1
3

Year Published

2010
2010
2024
2024

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 75 publications
(66 citation statements)
references
References 24 publications
4
58
1
3
Order By: Relevance
“…We measured (i) the angle between AAx and MAx and (ii) the shaft curve of the femur (CF) according to AAx (Figure 1), using MicroScribe G2X (Immersion Corp., San Jose, CA, USA) digitizer, the accuracy of the device is confirmed by previous study [19] and the data were obtained by Surfcam Velocity software (Surfware Inc., Camarillo, CA, USA) (Figure 2). …”
Section: Bone Measurementmentioning
confidence: 93%
“…We measured (i) the angle between AAx and MAx and (ii) the shaft curve of the femur (CF) according to AAx (Figure 1), using MicroScribe G2X (Immersion Corp., San Jose, CA, USA) digitizer, the accuracy of the device is confirmed by previous study [19] and the data were obtained by Surfcam Velocity software (Surfware Inc., Camarillo, CA, USA) (Figure 2). …”
Section: Bone Measurementmentioning
confidence: 93%
“…Biologically meaningful landmarks are the basis of face recognition and analysis [48], and were also previously used for symmetry analysis [1,5,14]. Recent investigations assessed the performance of contact instruments in clinical practice, and found their usage satisfactory, also considering that these instruments can be used directly in any environment, for instance quickly meeting the attractive subjects during beauty competitions, fashion events, or castings [30][31]49]. In contrast, optical instruments (laser scans, stereophotogrammetric digitizers) usually need dedicated locations, which often cannot be organized outside specialized laboratories.…”
Section: Study Limitationsmentioning
confidence: 99%
“…The facial landmarks are digitized one by one using a stylus connected to the digitizer. 2,4,7 Ultrasound probes use acoustic waves in the Megahertz frequency domain, while electromagnetic and electromechanic digitizers are based on electromagnetic waves. The main limitations of the instruments are the reduction of information obtained, and the data acquisition time, which is extremely long when compared to optical methods.…”
Section: Contact Instrumentsmentioning
confidence: 99%
“…Together with these classic measurements, mathematics and geometrics allow the assessment of more complex characteristics from the same set of landmarks used by conventional anthropometry: estimations of volumes and surfaces, analyses of symmetry, and detailed assessments of shape. [2][3][4][5]8 Three-dimensional morphomeTry meThods…”
mentioning
confidence: 99%