2014
DOI: 10.1016/j.neuroimage.2013.04.077
|View full text |Cite
|
Sign up to set email alerts
|

Methodology for improved detection of low concentration metabolites in MRS: Optimised combination of signals from multi-element coil arrays

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
96
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 57 publications
(99 citation statements)
references
References 31 publications
3
96
0
Order By: Relevance
“…Although the S/N weighting and S/N 2 weighting methods usually outperform the signal weighting method, it is interesting to find in our simulated experiments that extrinsic noise correlation likely degraded the performance of the S/N weighting and S/N 2 weighting methods compared with that of the signal weighting method, and more SNR would be compromised using the S/N 2 weighting method than the S/N weighting method, which were consistent with the theoretical analysis in this study. Of note, similar results were also reported in the recently published article that introduced the S/N 2 weighting method (21), but the reason underlying this interesting phenomenon was analyzed and verified in the present study for the first time.…”
Section: Discussionsupporting
confidence: 91%
See 2 more Smart Citations
“…Although the S/N weighting and S/N 2 weighting methods usually outperform the signal weighting method, it is interesting to find in our simulated experiments that extrinsic noise correlation likely degraded the performance of the S/N weighting and S/N 2 weighting methods compared with that of the signal weighting method, and more SNR would be compromised using the S/N 2 weighting method than the S/N weighting method, which were consistent with the theoretical analysis in this study. Of note, similar results were also reported in the recently published article that introduced the S/N 2 weighting method (21), but the reason underlying this interesting phenomenon was analyzed and verified in the present study for the first time.…”
Section: Discussionsupporting
confidence: 91%
“…The unsuppressed water signal was selected as the reference for computing the coil sensitivities and phase shifts of individual coil elements in this study (12)(13)(14)17,18,21), that is,…”
Section: Lðwþ5wmentioning
confidence: 99%
See 1 more Smart Citation
“…Briefly, the anatomical image was segmented into grey matter, white matter, and cerebrospinal fluid. MRS data acquired independently from the 32 channels were combined using an optimized coil combination method [50]. Metabolite concentrations were estimated using LCModel [51].…”
Section: Data Processingmentioning
confidence: 99%
“…This is typically tested via appropriate phantoms, usually provided by the manufacturer and/or vendor of the scanner, or specifically manufactured in the laboratory [3]. Such tests include not only signal-to-noise ratio (SNR) measurements, but also, particularly in larger, inhomogeneous RF coils, the SNR homogeneity across the sample volume [4][5][6][7][8][9][10][11][12]. Even more challenging would be the QC of hybrid systems like, e.g., PET/MRI [13].…”
Section: Some Notes Concerning Quality Control In (F)mri Mrs and Nmmentioning
confidence: 99%