2012
DOI: 10.2503/jjshs1.81.337
|View full text |Cite
|
Sign up to set email alerts
|

Methyl Jasmonate Treatment Enhanced Protodioscin Biosynthesis in White Asparagus (Asparagus officinalis L.) Spears

Abstract: The objective of this study was to clarify the factors that influence saponin biosynthesis, with an emphasis on protodioscin, a major saponin compound in white asparagus spears. We investigated the effects of methyl jasmonate (MeJM) treatment on protodioscin content in white spears harvested by spring semi-forced and winterforced cultivation. Protodioscin content was determined using high performance liquid chromatography equipped with an evaporative light scattering detector. Protodioscin was mainly localized… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

2
7
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 8 publications
(9 citation statements)
references
References 30 publications
2
7
0
Order By: Relevance
“…The samples of 18 different plant parts were pulverized for analysis. Rutin and protodioscin were extracted from 50 mg of freeze-dried powder with 1 mL of 70% ethanol according to the modification method of Maeda et al (2010Maeda et al ( , 2012 and Nikaido et al (2014). A highperformance liquid chromatography system (HPLC; Laboratory Solutions system; Shimadzu, Kyoto, Japan) equipped with an evaporative light scattering detector (ELSD-LTII detector; Shimadzu) and a photodiode array detector (SPD-M20A; Shimadzu) were used for quantification.…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…The samples of 18 different plant parts were pulverized for analysis. Rutin and protodioscin were extracted from 50 mg of freeze-dried powder with 1 mL of 70% ethanol according to the modification method of Maeda et al (2010Maeda et al ( , 2012 and Nikaido et al (2014). A highperformance liquid chromatography system (HPLC; Laboratory Solutions system; Shimadzu, Kyoto, Japan) equipped with an evaporative light scattering detector (ELSD-LTII detector; Shimadzu) and a photodiode array detector (SPD-M20A; Shimadzu) were used for quantification.…”
Section: Methodsmentioning
confidence: 99%
“…A highperformance liquid chromatography system (HPLC; Laboratory Solutions system; Shimadzu, Kyoto, Japan) equipped with an evaporative light scattering detector (ELSD-LTII detector; Shimadzu) and a photodiode array detector (SPD-M20A; Shimadzu) were used for quantification. HPLC conditions were as follows: 1.0 mL · min -1 flow rate, 40°C column temperature, a Waters Symmetry C18 column (4.6 · 250 mm; Nihon Waters K. K., Tokyo, Japan) with a security guard cartridge (3.0 · 4.6 mm), 0.1% trifluoroacetic acid: acetonitrile-water (by volume) mobile phase with a gradient condition, 354-nm wavelength of a photodiode array detector (Maeda et al, 2010(Maeda et al, , 2012Nikaido et al, 2014). A calibration curve was prepared using external standard rutin solution (Wako Pure Chemical Industries, Osaka, Japan) and protodioscin solution (Chroma-Dex Inc., Los Angeles, CA), and the rutin and protodioscin content were calculated from the peak area, respectively.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations