2009
DOI: 10.1016/j.nimb.2009.03.065
|View full text |Cite
|
Sign up to set email alerts
|

Micro-ERDA, micro-RBS and micro-PIXE techniques in the investigation of fish otoliths

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2009
2009
2016
2016

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(11 citation statements)
references
References 23 publications
0
11
0
Order By: Relevance
“…This is a reasonable approximation for the sample orientation used in the experiments, see above. The code RBS-MAST [7] would allow to handle RBS spectra obtained from 3D-structured samples by taking correlation effects and multiple surface crossings into account, but it does not take the various energyspread contributions (except detector resolution) into account [ 14 ]. This disadvantage, together with the easier usability of SIMNRA and the absence of correlation effects in our experiments, was the main reason to use the simpler approach of a linear superposition of sub-spectra.…”
Section: Methodsmentioning
confidence: 99%
“…This is a reasonable approximation for the sample orientation used in the experiments, see above. The code RBS-MAST [7] would allow to handle RBS spectra obtained from 3D-structured samples by taking correlation effects and multiple surface crossings into account, but it does not take the various energyspread contributions (except detector resolution) into account [ 14 ]. This disadvantage, together with the easier usability of SIMNRA and the absence of correlation effects in our experiments, was the main reason to use the simpler approach of a linear superposition of sub-spectra.…”
Section: Methodsmentioning
confidence: 99%
“…While all three techniques can be used for mapping (Huszank et al, 2009;Hinz and Kohn, 2010;Shirai et al, 2014), on otoliths they are generally used for transect analyses. Maps of otoliths from wild specimens by PIXE (Limburg et al, 2003;Huszank et al, 2009) and Sr-tagged specimens raised in tanks by SEM-EDX (Morales-Nin et al, 2012a) have been previously shown.…”
Section: Lateral Resolution and Data Alignment In Sclerochronologicalmentioning
confidence: 99%
“…While all three techniques can be used for mapping (Huszank et al, 2009;Hinz and Kohn, 2010;Shirai et al, 2014), on otoliths they are generally used for transect analyses. Maps of otoliths from wild specimens by PIXE (Limburg et al, 2003;Huszank et al, 2009) and Sr-tagged specimens raised in tanks by SEM-EDX (Morales-Nin et al, 2012a) have been previously shown. SR-μXRF scanning on a macro scale is a recent and actively developing technique in the study of both modern and ancient materials (Lintern et al, 2009;Bertrand et al, 2012;Anné et al, 2014).…”
Section: Lateral Resolution and Data Alignment In Sclerochronologicalmentioning
confidence: 99%
See 1 more Smart Citation
“…The measurement and data acquisition setup developed for the ion beam analysis of thin inhomogeneous samples [15][16][17] was used.…”
Section: Discussionmentioning
confidence: 99%