1977
DOI: 10.1093/clinchem/23.3.599
|View full text |Cite
|
Sign up to set email alerts
|

Micro-scale method for theophylline in body fluids by reversed-phase, high-pressure liquid chromatography.

Abstract: We describe a micro-scale method for determining serum theophylline. The chromatography system includes a muBondapack C18 column and acetonitrile, 70 ml/liter of sodium acetate buffer (10 mmol/liter, ph 4.0) as the mobile phase. Test serum or plasma, 30 mul, is mixed with an equal quantity of a solution containing the internal standard, beta-hydroxyethyltheophylline in acetonitrile/sodium acetate buffer (20 mmol/liter, pH 4.0), 7/43 by vol. After the precipitate is removed by centrifugation, the mixture is chr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0

Year Published

1977
1977
1989
1989

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 164 publications
(14 citation statements)
references
References 0 publications
0
12
0
Order By: Relevance
“…Serum theophylline concentrations were deter-mined by the high-peiformance liquid chromatography (HPLC) assay of Orcutt et al 18 Aiialysis of variance (AN0VA)'O and Scheffe's multiple comparison tes tszo were peiformed to detect differences in theophylliiie concentrations, and prothrombin and partial throinboplastiii times. In the theophylline group one of 65 samples was not obtained and its value was estimated by Yates'…”
Section: Methodsmentioning
confidence: 99%
“…Serum theophylline concentrations were deter-mined by the high-peiformance liquid chromatography (HPLC) assay of Orcutt et al 18 Aiialysis of variance (AN0VA)'O and Scheffe's multiple comparison tes tszo were peiformed to detect differences in theophylliiie concentrations, and prothrombin and partial throinboplastiii times. In the theophylline group one of 65 samples was not obtained and its value was estimated by Yates'…”
Section: Methodsmentioning
confidence: 99%
“…Plasma and urinary theophylline concentrations were estimated by high-pressure liquid chromatography (HPLC). In the case of plasma estimations, a modification of the method of Orcutt et al 15 was used. Theophylline was extracted from 100 ILl of acidified plasma into dichloromethane containing 8-chlorotheophylline as internal standard.…”
Section: Methodsmentioning
confidence: 99%
“…Serum theophylline was measured by the high pressure liquid chromatographic method of Orcutt, Kozak, Gillman & Cummings (1977) with minor modifications. The absorbance detector (Model 440, Waters Ass.)…”
Section: Analysis and Calculationsmentioning
confidence: 99%