Microbiosensors for glucose based on Prussian Blue modified carbon fiber electrodes for in vivo monitoring in the central nervous system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
25
0

Year Published

2014
2014
2018
2018

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 41 publications
(25 citation statements)
references
References 40 publications
0
25
0
Order By: Relevance
“…gold-coated screen-printed electrode as peroxide transducer for GOx [46] 0.68 up to 0.6 carbon fiber (250 mm length, 8 mm diameter) modified with peroxide transducer and GOx [47] 9.3 0.1-2 carbon fiber (200-500 mm length, 7 mm diameter) modified with GOx mediated by MnO2 [48] 22.7 1.5-15 carbon fiber (500 mm length, 30 mm diameter) modified with ruthenium as peroxide transducer for immobilized GOx [49] 20.5 0-4 this work 77 1-30…”
Section: Discussionmentioning
confidence: 99%
“…gold-coated screen-printed electrode as peroxide transducer for GOx [46] 0.68 up to 0.6 carbon fiber (250 mm length, 8 mm diameter) modified with peroxide transducer and GOx [47] 9.3 0.1-2 carbon fiber (200-500 mm length, 7 mm diameter) modified with GOx mediated by MnO2 [48] 22.7 1.5-15 carbon fiber (500 mm length, 30 mm diameter) modified with ruthenium as peroxide transducer for immobilized GOx [49] 20.5 0-4 this work 77 1-30…”
Section: Discussionmentioning
confidence: 99%
“…In this way, the biosensor was cycled in the presence of 1 mm glucose from 25 to 1000 mV s À1 ( Figure 6A). [73] [72] Figure 7 shows the chronoamperograms and the calibration curves obtained for 0.0 to 16 mm glucose (in phosphate buffer solution (PBS), pH 7.4, E app = À0.10 V) by using our nonoptimized DPR-700/Fe 3 O 4 @pDA150/Gox configuration.…”
Section: Ir Spectroscopymentioning
confidence: 99%
“…Data showed a linear dependence at low glucose concentrations and saturation at high concentrations, in agreement with the Michaelis-Menten kinetics. [73]…”
Section: Ir Spectroscopymentioning
confidence: 99%
See 1 more Smart Citation
“…At these potentials, however, endogenous reducing agents, such as ascorbic acid (AA), which is present in high concentrations in most biological tissues and fluids, can give rise to false positive biosensor responses in vivo . A permselective barrier is therefore essential in the design of implantable biosensors, and a range of electro-deposited poly-phenylenediamines [30,31,32,33,34,35] and polyphenols [36,37,38,39] have been developed to improve biosensor selectivity for brain monitoring where ECF ascorbate levels are particularly high (up to 1 mM) [40,41]. …”
Section: Introductionmentioning
confidence: 99%