2016
DOI: 10.4155/bio-2016-0008
|View full text |Cite
|
Sign up to set email alerts
|

Microextraction Techniques in Illicit Drug Testing: Present and Future

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 15 publications
0
2
0
Order By: Relevance
“…Moreover, target molecules in complex matrices, such as biological fluids, are often masked by the presence of other components in the sample that prevent their accurate characterization through vibrational spectroscopy [ 121 , 123 ]. One way to overcome such obstacles is the integration of SERS with separation techniques, such as thin-layer chromatography (TLC) [ 124 , 125 ], HPLC [ 119 ], chemical separation [ 98 ], and solid/liquid-phase extraction [ 126 ]. Another way is to use capture methods for selective detection and recognition of the target molecules combined with SERS.…”
Section: Discussionmentioning
confidence: 99%
“…Moreover, target molecules in complex matrices, such as biological fluids, are often masked by the presence of other components in the sample that prevent their accurate characterization through vibrational spectroscopy [ 121 , 123 ]. One way to overcome such obstacles is the integration of SERS with separation techniques, such as thin-layer chromatography (TLC) [ 124 , 125 ], HPLC [ 119 ], chemical separation [ 98 ], and solid/liquid-phase extraction [ 126 ]. Another way is to use capture methods for selective detection and recognition of the target molecules combined with SERS.…”
Section: Discussionmentioning
confidence: 99%
“…To have a determination of psychoactive substances and their metabolites with high mass accuracy, liquid chromatography can be coupled with high resolution mass spectrometry (MS) [12,13]. In modern illicit drug testing sample clean-up takes 50-75% of the total analysis time and remains one of the main bottlenecks [14]. Generally, to detect synthetic cannabinoids, commercial resins without http://dx.doi.org/10.1016/j.talanta.2017.01.072 Received 13 November 2016; Received in revised form 23 January 2017; Accepted 25 January 2017 any post functionalization are used to clean up samples like wastewater, human serum, whole blood, urine and hair [12,[15][16][17].…”
Section: Introductionmentioning
confidence: 99%