Microfabricated reciprocating micropump for intracochlear drug delivery with integrated drug/fluid storage and electronically controlled dosing

Abstract: The anatomical and pharmacological inaccessibility of the inner ear is a major challenge in drug-based treatment of auditory disorders. This also makes pharmacokinetic characterization of new drugs with systemic delivery challenging, because efficacy is coupled with how efficiently a drug can reach its target. Direct delivery of drugs to cochlear fluids bypasses pharmacokinetic barriers and helps to minimize systemic toxicity, but anatomical barriers make administration of multiple doses difficult without an a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
41
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 64 publications
(41 citation statements)
references
References 43 publications
0
41
0
Order By: Relevance
“…The basic electromagnetic actuator, pump chambers and valve architectures have been described previously (23). Briefly, Fig 1d shows a cross-section of the pump architecture consisting of two valves and a central pump chamber.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The basic electromagnetic actuator, pump chambers and valve architectures have been described previously (23). Briefly, Fig 1d shows a cross-section of the pump architecture consisting of two valves and a central pump chamber.…”
Section: Resultsmentioning
confidence: 99%
“…23 in an arrayed format that enables on-chip organ model perfusion and crosstalk for Microphysiological Systems (MPS) applications. We evaluate fluidic performance of the platform in supporting the demonstration of an interconnected circuit comprising four airway modules and one liver module with frequent fluid exchange between modules over the course of 14 days of operation.…”
Section: Introductionmentioning
confidence: 99%
“…b) A microfluidic reciprocating pump and electromagnetic actuators for intracochlear drug delivery. Reproduced with permission . Copyright 2016, The Royal Society of Chemistry.…”
Section: Utilization Of Wearables Sensory Datamentioning
confidence: 99%
“…For example, auditory disorders are common diseases of the elderly, but the drug delivery in the inner ear is relatively inaccessible both pharmacologically and anatomically, due to the cochlear barrier and the delicate anatomic structure of cochlea . Some attempts have been tried to deliver the drug into middle ear and onto the round window membrane to intensify therapeutic efficacy, however these delivery methods depend on passively diffusing of drugs, which is slow and unpredictable. Similar situation happens for the treatment of eye diseases, such as dry eye, cataract, and glaucoma .…”
Section: Clinical Diagnosis/therapeutics and Healthcarementioning
confidence: 99%
“…A) Photographs of the microfluidics portion of a micropump for drug storage and delivery. Reproduced with permission . Copyright 2016, The Royal Society of Chemistry.…”
Section: Clinical Diagnosis/therapeutics and Healthcarementioning