2015
DOI: 10.1016/j.chroma.2015.05.053
|View full text |Cite
|
Sign up to set email alerts
|

Microfabrication, separations, and detection by mass spectrometry on ultrathin-layer chromatography plates prepared via the low-pressure chemical vapor deposition of silicon nitride onto carbon nanotube templates

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
10
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
4
1
1

Relationship

1
5

Authors

Journals

citations
Cited by 20 publications
(10 citation statements)
references
References 38 publications
0
10
0
Order By: Relevance
“…SEM micrographs of CNTs conformally coated with ca. 38 nm layer of Si 3 N 4 and of microfabricated UTLC plates oxidized at 1000°C showing no expansion or distortions of the microfeatures …”
Section: Preparation Of Monolithic Layersmentioning
confidence: 96%
See 1 more Smart Citation
“…SEM micrographs of CNTs conformally coated with ca. 38 nm layer of Si 3 N 4 and of microfabricated UTLC plates oxidized at 1000°C showing no expansion or distortions of the microfeatures …”
Section: Preparation Of Monolithic Layersmentioning
confidence: 96%
“…Scanning UTLC‐direct analysis in real time mass spectrometry of the separated lipophilic dye mixture. Dimethyl Yellow (1), Oracet Red G (2), Solvent Blue 35 (3), Sudan Red G (4), Solvent Blue 22 (5), and Oracet Violet 2R (6) …”
Section: Preparation Of Monolithic Layersmentioning
confidence: 99%
“…The microfabrication of ultrathin-layer chromatography (UTLC) plates via conformal low-pressure chemical vapor deposition of silicon nitride onto patterned carbon nanotube (CNT) scaffolds, acting as surface templates, has been described by Kanyal et al [ 109 ]. The plates were heated and oxidized to both remove the CNTs and convert Si 3 N 4 into silica; finally, the plates were hydroxylated in aqueous ammonium hydroxide.…”
Section: Materials For Spray-based Ionization Techniquesmentioning
confidence: 99%
“…ID‐Cube and modified solid‐phase microextraction (SPME) . In addition to DART, other ambient ionization techniques have been used to collect MS data from (HP)TLC layers, mainly desorption electrospray ionization (DESI) and plasma‐assisted multi‐wavelength laser desorption ionization (PAMLDI) …”
mentioning
confidence: 99%
“…The spatial resolution at full width at half maximum was determined to be 0.8 mm and the scan lane width to be 3 mm . This optimized system was used to scan UTLC and HPTLC tracks to identify lipophilic food dyes and antibacterial compounds of essential oil …”
mentioning
confidence: 99%