2022
DOI: 10.1016/j.bios.2022.114487
|View full text |Cite
|
Sign up to set email alerts
|

Microfluidic-based exosome isolation and highly sensitive aptamer exosome membrane protein detection for lung cancer diagnosis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
40
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 74 publications
(40 citation statements)
references
References 34 publications
0
40
0
Order By: Relevance
“…Exo-CMDS is capable of isolating and purifying exosomes in a single step and has a highly qualified yield with an ideal exosome concentration of 5.1 × 10 9 particles per ml from trace blood samples (less than 300 μl) in only 8 minutes. 99 Urine is the second most important biological fluid after saliva because it can be collected quickly, painlessly, without special procedures or equipment, and because it can be obtained in large quantities. The best thing about using urine instead of tissue or blood is that taking urine isn't as painful as taking tissue or blood.…”
Section: Other Biological Fluidsmentioning
confidence: 99%
See 1 more Smart Citation
“…Exo-CMDS is capable of isolating and purifying exosomes in a single step and has a highly qualified yield with an ideal exosome concentration of 5.1 × 10 9 particles per ml from trace blood samples (less than 300 μl) in only 8 minutes. 99 Urine is the second most important biological fluid after saliva because it can be collected quickly, painlessly, without special procedures or equipment, and because it can be obtained in large quantities. The best thing about using urine instead of tissue or blood is that taking urine isn't as painful as taking tissue or blood.…”
Section: Other Biological Fluidsmentioning
confidence: 99%
“…Exo-CMDS is capable of isolating and purifying exosomes in a single step and has a highly qualified yield with an ideal exosome concentration of 5.1 × 10 9 particles per ml from trace blood samples (less than 300 μl) in only 8 minutes. 99…”
Section: Emerging Novel Poc Based Approach For Detection Of Liquid Bi...mentioning
confidence: 99%
“…The centrifugal microfluidic disc system (Exo-CMDS) is proposed by Zhao et al (2022) for the isolation of exosomes. The automated centrifugal microfluidic disc system is combined with a functionalized membrane to form Exo-CMDS.…”
Section: Capture By the Centrifugal Microfluidic Disc Systemmentioning
confidence: 99%
“…Despite fabrication challenges, microfluidic systems have the potential to integrate different mechanical parameters into one practical, inexpensive, and efficient device. The centrifugal microfluidic disc with functionalized membranes proposed by Zhao et al 35 is an example of such a multiparametric system that can isolate exosome from whole blood samples. The disc is composed of engraved units that communicate with each other by capillary channels and consists of two polycarbonate (PC) layers with the bottom layer engraved with six hydrophilically modified functional units (a loading chamber, a chamber for whole blood separation, a mixing chamber, an input for exosome loading buffer, an exosome isolating buffer chamber, and a commutator unit).…”
Section: Isolation Techniquesmentioning
confidence: 99%