2009
DOI: 10.1002/bit.22516
|View full text |Cite
|
Sign up to set email alerts
|

Microfluidic biochip for the perifusion of precision‐cut rat liver slices for metabolism and toxicology studies

Abstract: Early detection of kinetic, metabolic, and toxicity (ADME-Tox) profiles for new drug candidates is of crucial importance during drug development. This article describes a novel in vitro system for the incubation of precision-cut liver slices (PCLS) under flow conditions, based on a poly(dimethylsiloxane) (PDMS) device containing 25-microL microchambers for integration of the slices. The microdevice is coupled to a perifusion system, which enables a constant delivery of nutrients and oxygen and a continuous rem… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
121
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
7
2
1

Relationship

1
9

Authors

Journals

citations
Cited by 123 publications
(126 citation statements)
references
References 34 publications
2
121
0
Order By: Relevance
“…To overcome this adsorption problem, a number of PDMS surface treatments have been developed. Due to the porous structure of PDMS, coatings with a hydrophilic compound can be performed [383,385]. However, the coatings might influence cell responses [386].…”
Section: Discussionmentioning
confidence: 99%
“…To overcome this adsorption problem, a number of PDMS surface treatments have been developed. Due to the porous structure of PDMS, coatings with a hydrophilic compound can be performed [383,385]. However, the coatings might influence cell responses [386].…”
Section: Discussionmentioning
confidence: 99%
“…The precision cut liver slice (100 mm thick, 4 mm diameter) was perfused by a 10 ml min 21 media flow in an incubator chamber with constant pH and dissolved oxygen. 71 In a human setting, the tissue used here would correspond to approximately two liver lobules (around 2 6 10 5 liver cells). Biotransformation activity was shown to be equal in control slices in static culture over three hours.…”
Section: Endothelial Sinusoid Model and Hepatic Lobule ''Equivalent''mentioning
confidence: 99%
“…Since precision-cut liver slice was reported in the early 1980s [6], it has became more and more mature and perfect along with the improvement of culture method [1] [7] [8]. Precision-cut liver slice has been successfully used in the study of drug toxicity mechanism and prediction, the discovery of early toxicity markers and drug metabolism and transformation.…”
Section: Introductionmentioning
confidence: 99%