Microfluidic Chip with Two-Stage Isothermal Amplification Method for Highly Sensitive Parallel Detection of SARS-CoV-2 and Measles Virus

Abstract: A two-stage isothermal amplification method, which consists of a first-stage basic recombinase polymerase amplification (RPA) and a second-stage fluorescence loop-mediated isothermal amplification (LAMP), as well as a microfluidic-chip-based portable system, were developed in this study; these enabled parallel detection of multiplex targets in real time in around one hour, with high sensitivity and specificity, without cross-contamination. The consumption of the sample and the reagent was 2.1 μL and 10.6 μL pe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
11
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(11 citation statements)
references
References 39 publications
0
11
0
Order By: Relevance
“…The whole assay was completed within 70 min with an LOD of two copies/reaction [ 102 ]. Xiong H et al developed a rotating microfluidic fluorescence system detection based on RT-LAMP, Ramachandran A et al developed isotachophoresis coupled RT-LAMP based amplification and clustered regularly interspaced short palindromic repeats (CRISPR)–Cas12 based detection, Huang Q et al developed a portable microfluidic chip-based system with two-stage isothermal amplification, Soares et al developed the modular centrifugal microfluidic platform to perform RT-LAMP, all detect nucleic acids of SARS-CoV-2 by fluorescence-based detection [ 103 , 104 , 105 , 106 ]. The limit of detection of rotating microfluidic fluorescence systems detection based on RT-LAMP and isotachophoresis coupled RT-LAMP based amplification and CRISPR–Cas12 based detection is the same (10 copies/μL).…”
Section: Microfluidics In Sars-cov-2mentioning
confidence: 99%
See 2 more Smart Citations
“…The whole assay was completed within 70 min with an LOD of two copies/reaction [ 102 ]. Xiong H et al developed a rotating microfluidic fluorescence system detection based on RT-LAMP, Ramachandran A et al developed isotachophoresis coupled RT-LAMP based amplification and clustered regularly interspaced short palindromic repeats (CRISPR)–Cas12 based detection, Huang Q et al developed a portable microfluidic chip-based system with two-stage isothermal amplification, Soares et al developed the modular centrifugal microfluidic platform to perform RT-LAMP, all detect nucleic acids of SARS-CoV-2 by fluorescence-based detection [ 103 , 104 , 105 , 106 ]. The limit of detection of rotating microfluidic fluorescence systems detection based on RT-LAMP and isotachophoresis coupled RT-LAMP based amplification and CRISPR–Cas12 based detection is the same (10 copies/μL).…”
Section: Microfluidics In Sars-cov-2mentioning
confidence: 99%
“…This assay demonstrated 94.12% specificity and 95.83% sensitivity for SARS-CoV-2 with a very low detection limit of about 10 copies. So, it is ideal for resource-constrained areas and point-of-care testing (POCT) ( Table 3 ) [ 105 ].…”
Section: Microfluidics In Sars-cov-2mentioning
confidence: 99%
See 1 more Smart Citation
“…In another set of studies, the microfluidic chamber is integrated with LAMP and RPA for the detection of SARS-CoV-2 and measles virus (MV) in parallel simultaneously by the fluorescence signal change. This point-of-care testing method showed 100% clinical specificity and sensitivity for MV and 94.12% specificity and 95.83% sensitivity for SARS-CoV-2 with the LOD of ten copies within one hour [ 46 ].…”
Section: Biomarkers In Covid-19mentioning
confidence: 99%
“…To reach the goal of developing lower-cost and easy to use point-of-care analysis systems, Qin Huang et al [3] propose a novel microfluidic lab-on-chip for isothermal parallel detection of multiple targets. The approach is based on a two-stage recombinase polymerase amplification and subsequent loop-mediated isothermal amplification (RPA + LAMP) microfluidic platform, which is demonstrated in a disc-shaped milled PMMA lab-on-chip.…”
mentioning
confidence: 99%